HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 49

Hp storageworks fabric os 6.2.1 release notes (5697-0275, december 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Repeatedly disconnecting and reconnecting ISL links between the HP
StorageWorks Encryption SAN Switch in an HA cluster environment
while rekey operations are in progress may cause data miscompare.
Internal recovery scheme can attempt to correct a valid Frame Redirec-
tion RAM Filter, which can lead to one existing filter being corrupted,
potentially causing misrouted frames. This is a very rare occurrence.
Running configdefault may cause kernel panic on an HP Storage-
Works 4/256 SAN Director.
An unexpected switch panic can occur when supportsave reads
invalid data on GE ports without FC Fast Write enabled.
FICON XRC times out on a 400 MP Router to an HP DC SAN Director,
which causes drives not to come online.
Need support in Fabric OS for DWDM-SFP media.
HP StorageWorks 8/40 SAN Switch did not indicate a warning when
a PS/FAN FRU was removed.
High temperature alerts are reported on an HP StorageWorks DC
Switch Encryption Blade when the ambient temperature is 39
Fabric OS 6.2.0d fixes
Table 12
lists defects closed in the Fabric OS 6.2.0d firmware release.
Table 12 Fabric OS 6.2.0d closed defects
Closed defect summary
Brocade 8-Gb SAN Switch for HP BladeSystem c-Class requires up-
dated serdes values for proper operation with 8-Gb mezzanine HBAs.
An out-of-memory condition can occur, leading to a switch panic due
to memory leak when an E_Port constantly goes on and off.
An out-of-memory condition can occur during hafailover/hare-
boot, leading to a switch panic due to memory leak when querying
connUnitPortFCId in Access Gateway mode, as well as when
querying FcFeModuleName.
On rare occasions, HP StorageWorks DC SAN Director may panic in
RTE module and hafailover during supportsave.
During HA recovery, Fabric Watch reports switch health as margin-
al/down on fully populated HP StorageWorks DC SAN Director. Traffic
is not impacted, but DCFM call home will not be initiated.
After HAfailover, SNMP v3 user configuration reverts back to default
values when configuring SNMP v3 user configuration on any one of
the user-defined USM configuration sets.
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Enabled new SFP support in Fabric
OS 6.2.0c
Fixed in Fabric OS 6.2.0c
Fixed in Fabric OS 6.2.0c
o
Celsius.
Solution
Updated serdes values are provided
in Fabric OS 6.2.0d.
Fixed in Fabric OS 6.2.0d
Workaround prior to upgrade: Avoid
querying FcFeModuleName or
connUnitPortFCId in AG mode.
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d