Fabric OS 6.2.0b fixes
Table 10
lists defects closed in the Fabric OS 6.2.0b firmware release.
Table 10 Fabric OS 6.2.0b closed defects
Closed defect summary
CUP can fail to send CU-End to clear busy. CUP is still responsive, but
the host is waiting for the CUE.
WWN card FRU replacement does not send async reports to FICON
host, so that customers do not know when a WWN card has been
removed.
Customers may experience high CPU load and unexpected blade errors
due to an ASIC-generated interrupt handling problem.
Unable to configure ports using configdownload if the ports are
not physically present in the director (blade not plugged in).
On HP StorageWorks DC SAN Director, after running fosconfig
--enable vf, followed by fosconfig --disable vf, customer
cannot log in via Telnet or serial port, and a Cannot assign valid
AD at the login session error occurs.
When activating a saved PDCM Matrix from activate CUP Port
Connectivity Configuration dialog in Web Tools, with Act-
ive=Save Mode checked, Web Tools displays an error.
c-Class Onboard Administrator is unable to read the switchname
for Brocade 8Gb SAN Switch for HP BladeSystem c-Class.
End-to-end data frames in one direction of bidirectional I/O not re-
covered after switchdisable and switchenable on a Base switch.
Unexpected software call traceback error messages occasionally being
displayed on DC04 console.
Frame drops sometimes occur when a trunk port comes online, even
with Lossless DLS feature enabled.
Interactive mode stores supportsave files in switch root directory
rather than the USB device, which can also result in compact flash
storage overflow.
Solution
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b
Workaround prior to upgrade: Do not
change VF mode until dual CP chassis
is in sync
Fixed in Fabric OS 6.2.0b.
Workaround prior to upgrade:
Activate the same PDCM Matrix from
Web Tools with Active=Save
Mode check from Edit CUP Port
Connectivity configuration
window.
Fixed in Fabric OS 6.2.0b
Workaround prior to upgrade: The
switch name can be displayed from
Fabric OS CLI command
switchname
Fixed in Fabric OS 6.2.0b
Workaround prior to upgrade: Stop
and restart I/O may recover.
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b
Fixed in Fabric OS 6.2.0b