w i r i n g t a b L e • S L 3 0 0 0 u L 1 H P ™
J #
J Pin #
J1
1
J1
2
J1
3
J1
4
J1
5
J1
6
J1
7
J1
8
J1
9
J1
10
J2
10 Pins
J3
1
J3
2
J3
3
Normally Closed (No Wire)
J3
4
J3
5
Limit Switch Brown Com
J3
6
J3
7
J3
8
J3
9
Limit Switch Yellow Com
J3
10
Limit Switch Orange N.O.
J5
1
J5
2
Reset Switch, Interlock Red
J5
3
J5
4
Reset Switch, Interlock Black
J5
5
J5
6
J5
7
J6
1
J6
2
J6
3
J6
4
J7
1
J7
2
J7
3
J8
1
J8
2
J8
3
Plug-In Safety Loop Wire
J8
4
Plug-In Safety Loop Wire
J8
5
Plug-In Center Loop Wire
J8
6
Plug-In Center Loop Wire
J9
16 Pins
J10
1
J10
2
J10
3
J11
10 Pins
J12
10 Pins
J13
10 Pins
J1
1
J1
2
J1
3
J1
4
J1
5
J1
6
J1
1
J1
2
J1
3
J2
Fire Dept. Key Switch (7)
1
J2
2
Fire Dept. Key Switch (8)
J2
3
Strike Open Push Button (9)
J2
4
Strike Open Push Button (10)
J2
5
J2
6
J2
7
J3
1
J3
2
J3
3
Safety External Loop Detector (3)
J3
4
Safety External Loop Detector (4)
Exit External Loop Detector (5)
J3
5
Exit External Loop Detector (6)
J3
6
OmniControl™ Board
Signal Type
Safety Loop
Input Power Neutral
Not Used
Input Power 120Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Receiver +
Omni Option Board
Limit Switch Red N.O.
–
–
–
Purple Com
Blue N.O.
–
–
–
–
–
UL Alarm Red
UL Alarm Black
Safety Sensor
Safety Sensor
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
Plug-In Exit Loop Wire
Plug-In Exit Loop Wire
1 HP Board
G M/S Link
B M/S Link
A M/S Link
Not Used
Safety Loop Detector
Exit Loop Detector
Motor Red
Motor Black
Motor White Neutral
–
Motor Black
Motor White Neutral
OmniControl™ Surge Suppressor
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
Radio Receiver – (11)
Radio Receiver (12)
Radio Receiver + (13)
Not Used
Not Used
Direction
Level (+/- 10%)
In
5 or 0Vdc
In
–
In
120Vac
In
5 or 0Vdc
In
5 or 0Vdc
In
In
In
Out
Out
In
5 or 0Vdc
–
In
5 or 0Vdc
–
In
–
In
In
5 or 0Vdc
In
In
5 or 0Vdc
In
In
In
In
In
In
In
Out
Out
In
5 or 0Vdc
In
In
5 or 0Vdc
In
In
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
In
120Vac
In/Out
In/Out
5 or 0Vdc
In/Out
5 or 0Vdc
–
In
5 or 0Vdc
In
5 or 0Vdc
1 HP Board
Out
Out
120Vac
Out
–
Out
120Vac
Out
In/Out
5 or 0Vdc
In/Out
5 or 0Vdc
In/Out
In
In
5 or 0Vdc
In
In
In
5 or 0Vdc
In
Out
–
–
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
In
2 to 10Vdc
40
Input Connection
0V
External Loop Detector
–
120Vac Power,
Radio Receiver,
Strike Open,
0V
Key Switch
0V
Harness
Dry
24Vdc
24Vdc
Omni Option Board Input
–
–
Limit Switches,
0V
Maglock/Solenoid
–
Harness
0V
0V
–
Dry
Reset Switch and
–
Interlock Assembly
Dry
–
–
–
24Vdc
UL Alarm and
0Vdc
Safety Sensors
0V
Relay Adapter
0Vdc
Module Input
0Vdc
Plug-In Loop
Detector
Loop Wire Inputs
1 HP Board Input
0Vdc
Master/Second Link
–
Plug-In Loop
Detector Inputs
0V
2 Motors Input
0V
–
0V
0V
Master/Second Link
Dry
Dry
Radio Receiver,
Strike Open Push Button,
0V
Fire Dept Key Switch
0V
24Vdc
–
External Loop
–
Detector Center,
Safety, Exit Wires
NOTE: See diagram on previous page.
Wires,
Input
Input
Inputs
Input