Echo PB-2400 Operator's Manual page 21

Echo power blower operator's manual model type 1e
Table of Contents

Advertisement

6. Thread the rope through the eyelet in the housing (C) then
through the starter handle (D). Follow the illustration and tie
another knot in the free end of the rope. Pull the knot into the
handle.
7. Check that the hook (E) on the end of the spring touches the post
(F). Lightly grease the top of the spring and the post.
8. Hold the drum pawl side up and wind the rope on the drum
counterclockwise, four (4) turns.
9. Install drum. The loop in the spring must engage the slot in the
drum. Replace the screw and washer.
10. Hold the rope in the notch (G) and rotate the drum counterclock-
wise several turns.
11. Hold the drum to prevent it from rewinding, pull the excess rope
taught with the handle and allow to rewind slowly.
12. Pull rope several times to check spring tension. If rope does not
rewind fully, repeat 10.
13. Pull rope out all the way. Drum must be able to turn an addi-
tional 1/2 turn counter clockwise. If drum does not turn, see your
Authorized ECHO Service Dealer.
14. Install starter and test.