The J-EX8208 Ethernet switch is available as a fully redundant system. A redundant
J-EX8208 switch configuration is designed so that no single point of failure can cause
the entire switch to fail. See "J-EX8208 Switch Configurations" on page 6.
This topic describes:
Hardware Components That Provide Redundancy on page 9
Routing Engine and Control Redundancy on page 10
Switch Fabric Redundancy on page 10
The following hardware components provide redundancy to a J-EX8208 switch:
SRE modules—A redundant J-EX8208 switch has two Switch Fabric and Routing
Engine (SRE) modules. When two SRE modules are installed, one SRE module functions
as the master and the other functions as the backup. If the master SRE module fails
or is removed the backup module takes over as the master SRE module.
When the SRE modules are configured for graceful switchover, the backup SRE module
automatically synchronizes its configuration and state with those of the master SRE
module. Any update to the master SRE module is replicated on the backup SRE module.
If the backup module assumes mastership, packet forwarding continues through the
switch.
Power supplies—You can install up to six AC power supplies in a J-EX8208 switch.
Each power supply connects to the backplane of the chassis, which distributes the
output power produced by the power supplies to different switch components. (See
"Backplane in a J-EX8208 Switch" on page 41.) Each power supply provides power to
all the components in the switch.
An N+1 power configuration is required for J-EX8200 Ethernet switches. In an N+1
power configuration, if one power supply fails or is removed, the remaining power
supplies continue to supply power for the entire system without interruption. If dual
power feed redundancy is required, the required power configuration is N+N. See "AC
Power Supply in a J-EX8200 Switch" on page 34.
Cooling system—The cooling system in a J-EX8200 switch consists of a single fan tray.
The fan tray contains 12 fans. Under normal operating conditions, the fans in the fan
tray run at less than full speed.
The fans are controlled by two fan tray controllers. The fans are numbered 1 through
12. Fans 1 through 6 are controlled by the first fan tray controller. Fans 7 through 12 are
controlled by the second fan tray controller. If one fan tray controller fails, the other
fan tray controller keeps half the fans working. This allows the switch to continue to
operate normally as long as the remaining fans cool the chassis sufficiently.