Internal Chassis View; Rails And Cable Management; Fans; Figure 10. R910 Internal View - Dell External OEMR R910 Technical Manual

Technical guide
Hide thumbs Also See for External OEMR R910:
Table of Contents

Advertisement

Dell

4.7 Internal Chassis View

4.8 Rails and Cable Management

TM
ReadyRails
Sliding Rails for 4-post racks support the following:
Toolless installation in 19‖ EIA-310-E compliant square or unthreaded round hole 4-post racks
including all generations of Dell racks (Note: Threaded 4-post racks require Dell's fixed shelf
rd
or 3
party adapter brackets available through Dell Software & Peripherals.)
Full extension of the system out of the rack to allow serviceability of key internal components
Optional cable management arm (CMA) except on racks less than 1m in depth including Dell
4200 & 2400 racks
Measurements and adjustment ranges for the rack:
Rail depth without the CMA: 755 mm
Rail depth with the CMA: 883 mm
Square-hole rack adjustment range: 686–883 mm
Round-hole rack adjustment range: 672–876 mm
See Section 16 for more information.

4.9 Fans

Six 120mm single-rotor hot-swappable fans are mounted in a fan bay in the rear of the chassis. Each
fan has a single wire harness that plugs into the planar fan connectors (FAN1 through FAN6).
The Embedded Server Management (ESM) logic in the system controls and monitors the speed of the
fans. A fan speed fault or over-temperature condition results in a notification by ESM.
The R910 Power Supply Units have integrated fans. The system requires a blank in place of the empty
power supply slot. System fan speed is pulse-width modulated.
The iDRAC6 controls and monitors the speed of the fans. A fan speed fault or over-temperature
condition results in a notification by iDRAC6.
Dell PowerEdge R910 Technical Guide

Figure 10. R910 Internal View

21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r910

Table of Contents