4.7 Internal Chassis View
4.8 Rails and Cable Management
TM
ReadyRails
Sliding Rails for 4-post racks support the following:
Toolless installation in 19‖ EIA-310-E compliant square or unthreaded round hole 4-post racks
including all generations of Dell racks (Note: Threaded 4-post racks require Dell's fixed shelf
rd
or 3
party adapter brackets available through Dell Software & Peripherals.)
Full extension of the system out of the rack to allow serviceability of key internal components
Optional cable management arm (CMA) except on racks less than 1m in depth including Dell
4200 & 2400 racks
Measurements and adjustment ranges for the rack:
Rail depth without the CMA: 755 mm
Rail depth with the CMA: 883 mm
Square-hole rack adjustment range: 686–883 mm
Round-hole rack adjustment range: 672–876 mm
See Section 16 for more information.
4.9 Fans
Six 120mm single-rotor hot-swappable fans are mounted in a fan bay in the rear of the chassis. Each
fan has a single wire harness that plugs into the planar fan connectors (FAN1 through FAN6).
The Embedded Server Management (ESM) logic in the system controls and monitors the speed of the
fans. A fan speed fault or over-temperature condition results in a notification by ESM.
The R910 Power Supply Units have integrated fans. The system requires a blank in place of the empty
power supply slot. System fan speed is pulse-width modulated.
The iDRAC6 controls and monitors the speed of the fans. A fan speed fault or over-temperature
condition results in a notification by iDRAC6.