JVC GD-42X1U - Wide Gamut Hd Monitor Instructions Manual page 58

Instruction manual
Hide thumbs Also See for GD-42X1U - Wide Gamut Hd Monitor:
Table of Contents

Advertisement

Command outline
To control the monitor from external control equipment, send operation
commands to the monitor.
Example of communication procedures
External control
equipment
1 Operation command to select "Input-3".
2 Acknowledgment from the monitor.
3 The input is changed to "Input-3".
Command structure
! 0x82 0x80 IP 3 Lf
a
a: Header
b: Device ID
c: Monitor ID
d: Command
e: Data
f:
Termination
1
! 0x82 0x80 IP 3 Lf
2
Ack 0x82 0x80 IP 3 Lf
b
c
! : Operation command from the external control
device.
? : Enquiry command from the external control
device.
@ : Response from the monitor to an enquiry
command.
Ack (0x06): Positive acknowledge from the monitor.
Nak (0x15): Negative acknowledge from the
monitor.
0x82 (fixed)
0x80 – 0xFF (Default setting is 0x80.)
See "Command list" on the next page.
Lf (0x0A)
GD-42X1
d
e
f
3
39