Viewing Fabric Topology; Operating Status Symbols - HP 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Fw v06.xx/hafm sw v08.02.00 hp storageworks embedded web server user guide (aa-rtdrc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Viewing Product and Fabric Data
The symbols that display behind the product graphic indicate the status of the
product. The meaning of each symbol is explained in
Table 7: Operating Status Symbols
Symbol

Viewing Fabric Topology

The topology of a fabric is a high-level view of the routing and pathways on the
fabric. To view the fabric topology from the viewpoint of the hosting machine,
perform the following procedure:
1. Choose View from the navigation panel.
114
— Generic product. All other HP products in the fabric have a generic
product graphic. The generic product graphic does not provide a link to
the device's default page.
Symbol
Name
Green
Circle
Yellow
Triangle
Red
Diamond
Status
Fully Operational
Redundant Failure
Minor Failure
NOT OPERATIONAL
Table
7.
Meaning
All components and installed
ports are operational; no
failures.
A redundant component has
failed, such as a power supply,
and the backup component has
taken over operation.
A failure occurred that has
decreased the product's
operational ability. Normal
switching operations are not
affected.
One or more ports failed, but at
least one port is still operational.
A fan has failed or is not
rotating sufficiently.
A critical failure prevents the
product from performing
fundamental operations.
All fans failed.
All installed ports failed.
Both power supplies failed.
Embedded Web Server User Guide