Map 0600: Port Failure And Link Incident Analysis - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

15
Inspect fan module operational states at the EWS interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
2. Inspect the Status fields for both power supplies.
Does the Status field display a Failed message for either fan module?
NO
16
Inspect switch CTP operational states at the EWS interface. Inspect the Status
fields for the switch CTP.
Does the Status field display a Failed message for the CTP?
NO
Additional analysis is not described in this MAP. Go to
on page 33. If this is the second time at this step, contact the next level of support.
Exit MAP.

MAP 0600: Port Failure and Link Incident Analysis

This MAP describes fault isolation for shortwave laser small form factor
pluggable (SFP) optical transceivers, and longwave laser SFP optical transceivers;
and for Fibre Channel link incidents. Failure indicators include:
Edge Switch 2/24 Service Manual
Properties tab) displays.
YES
A fan module failure is indicated. Go to
YES
A CTP card failure is indicated. Replace the switch.
Exit MAP.
One or more amber LEDs on the ports illuminate.
One or more emulated amber LEDs on a port graphic at the Hardware View
illuminate.
A blinking red and yellow diamond (failed FRU indicator) displays over a
port graphic or a yellow triangle (attention indicator) displays at the alert
panel of the Products View or Hardware View.
An event code recorded at the Event Log or the EWS Event Log.
A port operational state message or a Failed message associated with a port
at the EWS interface.
Diagnostics
step
5.
"MAP 0000: Start
MAP"
93

Advertisement

Table of Contents
loading

Table of Contents