Diagnostics
MAP 0600: Port Failure and Link Incident Analysis
This MAP describes fault isolation shortwave laser small form factor pluggable (SFP)
optical transceivers, and longwave laser SFP optical transceivers; and for Fibre
Channel link incidents. Failure indicators include:
•
One or more amber LEDs on the ports illuminate.
•
One or more emulated amber LEDs on a port graphic at the Hardware View
illuminate.
•
A blinking red and yellow diamond (failed FRU indicator) appears over a port
graphic or a yellow triangle (attention indicator) appears at the alert panel of the
Products View or Hardware View.
•
An event code recorded at the Event Log or the EWS Event Log.
•
A port operational state message or a Failed message associated with a port at
the EWS interface.
•
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
•
A link incident event code recorded at the console of an OSI server attached to the
switch reporting the problem.
1
Was an event code 080, 081, 504, 505, 506, 507, 512, 514, or 802 observed at the
HAFM Event Log or at the EWS Event Log?
NO
YES
Go to
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an OSI
server attached to the switch reporting the problem?
YES
NO
Go to
2–64
step
3.
step
4.
edge switch 2/24 service manual