Link Incident Log - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Did one of the listed messages appear in the Link Incident Log?
YES
A link incident problem is indicated. Go to
event codes are found, go to
Problem
21
Obtain event codes from the Edge Switch 2/24 Event Log.
Note:
Record the date, time, and listed sequence, and determine if the codes are related to
the reported problem. Begin fault isolation with the most recent event code with the
highest severity level. Other codes may accompany this event code, or may indicate a
normal indication after a problem is recovered.
1. At the Hardware View, click Logs and select Event Log. The Event Log
2. Record the event code, date, time, and severity (Informational, Minor,
3. Record all event codes that may relate to the reported problem.
Figure 8: Event Log
Were one or more event codes found?
NO
Return to the MAP step that sent you here.
22
Are you at the switch reporting the problem?
YES
Edge Switch 2/24 Service Manual
NO
The switch appears operational. Exit MAP.
Determination" on
If multiple event codes are found, note all codes and associated severity levels.
displays.
Major, or Severe).
YES
Go to
Table
NO
Go to
step
34.
step 21
"MAP 0700: Fabric, ISL, and Segmented Port
page 107
. Exit MAP.
4.
to obtain event codes. If no
Diagnostics
43