Detailed Description Of Maintenance-Mode Functions; Eeprom Parameter Initialization - Brother IntelliFax-2600 Service Manual

Service manual
Table of Contents

Advertisement

3. DETAILED DESCRIPTION OF
MAINTENANCE-MODE FUNCTIONS
3.1

EEPROM Parameter Initialization

Function
The equipment initializes the parameters, user switches, and firmware switches registered in the
EEPROM, to the initial values. Entering the function code 01 initializes all of the EEPROM areas,
but entering 91 does not initialize some areas, as listed below.
Data item
Maintenance-mode functions
User switches
Firmware switches
Activity report
Station ID data
Remote activation code
Outside line number
Telephone function registration
One-touch dialing
Speed dialing
Group dialing
EEPROM customizing code
(4-digit)
NOTE: If you replace the main PCB with one used for other facsimile equipment, carry out this
procedure to initialize the EEPROM and then customize it (maintenance-mode function code 74 in
Section 3.9).
Operating Procedure
(1) Press the 0 and 1 keys (or the 9 and 1 keys according to your need) in this order in the initial
stage of the maintenance mode.
The "PARAMETER INIT" will appear on the LCD.
(2) Upon completion of parameter initialization, the equipment returns to the initial stage of the
maintenance mode.
Function code
(Note that the first digit of code xx01 will be initialized
to "0." If the code is 1001, for example, it will be
initialized to 0001.)
V - 4
01
All of these will be
initialized
This will not be initialized.
91
These will be
initialized
These will not be
initialized