Download Print this page

Bosch 1506 - Unishears - Net Weight: 6 Lbs Operating/Safety Instructions Manual page 9

Operating instructions
Hide thumbs Also See for 1506 - Unishears - Net Weight: 6 Lbs:

Advertisement

Available languages

Available languages

BM 3609929845 3-04
3/8/04
Service
Preventive maintenance
WARNING
!
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could
cause
serious
recommend that all tool service be
performed by a Bosch Factory Service
Center or Authorized Bosch Service Station.
TOOL LUBRICATION
Your Bosch tool has been properly
lubricated and is ready to use. It is
recommended that tools with gears be
regreased with a special gear lubricant at
every brush change.
CARBON BRUSHES
The brushes and commutator in your tool
have been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend
every two to six months the brushes be
examined. Only genuine Bosch replacement
brushes specially designed for your tool
should be used.
BEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
If an extension cord is
!
WARNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles.
NOTE: The smaller the gauge number, the heavier
the cord.
* Upper and lower blade set 2 607 010 025
* Hex key (5mm)
** Carrying case
10:17 AM
Page 9
Maintenance
should be replaced at Bosch Factory
Service Center or Authorized Bosch Service
Station. Bearings which become noisy (due
to heavy load or very abrasive material cut-
ting) should be replaced at once to avoid
overheating or motor failure.
hazard.
We
WARNING
!
the power supply before cleaning or
performing any maintenance. The tool may
be
cleaned
compressed dry air. Always wear safety
goggles when cleaning tools with
compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
!
CAUTION
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
Accessories
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
3-6
18
6-8
18
8-10
18
10-12
16
12-16
14
(*= standard equipment)
(**= optional accessories)
-9-
Cleaning
To avoid accidents always
disconnect the tool from
most
effectively
with
Certain cleaning agents
and
solvents
damage
2
Wire Sizes in mm
Cord Length in Meters
50
100 150
15
30
60
120
16
16
14
0.75 0.75 1.5
2.5
16
14
12
0.75 1.0 2.5
4.0
16
14
12
0.75 1.0 2.5
4.0
16
14
12
1.0 2.5 4.0
12

Hide quick links:

Advertisement

loading