Specifications
Dimensions (HxWxD): 5 in. x 2.8 in. x 2.2 in.
Input Power:
Standby Power:
Alarm Relay:
Tamper:
Temperature Range:
Microwave Frequency:
DS950:
DS950A:
DS950B:
Coverage:
Broad (standard):
Long Range (optional): 100 ft. by 10 ft. (30 m by 3 m)
Internal Pointability:
Options:
Use of a bracket may reduce range and increase dead zone
NOTE:
areas.
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at:
datecodes/.
(12.7 cm x 7.1 cm x 5.6 cm)
9 VDC to 15 VDC, 22 mA DC nominal
(up to 52 mA DC during walk testing,
stored alarms, or trouble conditions).
Use only an Approved Limited Power
Source.
No internal standby battery.
Standby power must be provided by
an Approved Limited Power Source.
For each hour of standby time
needed, 22 mAh is required. A
minimum of 4 hrs. (88 mAh) is
required for UL Listed requirements.
Silent operating Form "C" reed relay.
Contacts rated 3 W, 125 mA,
28 VDC maximum for DC resistive
loads; and protected by a 4.7
0.5 W resistor in the common "C"
leg of the relay. To be connected to a
SELV (Safety Extra-Low Voltage) circuit
only. Do not use with capacitive or
inductive loads.
Normally Closed (with cover on).
Contacts rated at 28 VDC, 125 mA
max. To be connected to a Safety
Extra-Low Voltage (SELV) circuit only.
Connect tamper circuit to 24-hour
protection circuit.
-40°F to +120°F (-40°C to +49°C).
For UL Listed requirements, the
temperature range is +32°F to +120°F
(0°C to +49°C), indoor use.
10.525 GHz (UL Listed)
10.687 GHz (Export only, not UL
Listed)
9.9 GHz (Export only, not UL Listed))
50 ft. by 50 ft. (15 m by 15 m)
+2° to –10° Vertical, ±10° Horizontal.
B328 Gimbal Mount Bracket, B335
Low Profile Swivel Mount Bracket,
B338 Ceiling Mount Bracket, OLR92
Long Range Barrier Lens, TC6000
Test Cord
http://www.boschsecurity.com/
Compliance: This device complies with Part 15 of the FCC Rules
and with RSS-210 of Industry and Science Canada. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesirable
operation.
Changes or modifications not expressly approved by Bosch
Security Systems can void the user's authority to operate the
equipment.
2.0
Installation Considerations
The DS950 is not recommended for installations containing
NOTE:
pets or small animals. Use the DS820 or DS835 for such
installations.
Never install the detector in an environment that causes an alarm
condition in one technology. Good installations start with the LED
OFF when there is no target motion. It should never be left to
operate with the tri-color LED in a constant or intermittent green,
yellow, or red condition.
Point the unit away from outside traffic (roads/alleys).
Microwave energy will pass through glass and most
NOTE:
common non-metallic construction walls.
,
Avoid installations where rotating machines (e.g. ceiling fans)
are normally in operation within the coverage pattern. Point the
unit away from glass exposed to the outdoors and objects that
may change temperature rapidly.
The PIR detector will react to objects rapidly changing
NOTE:
temperature within its field-of-view.
Eliminate interference from nearby outside sources.
3.0
Mounting
Select a location likely to intercept an intruder moving across the
coverage pattern. The surface should be solid and vibration-
free. Mounting height range is 6 to 8 feet (1.8 to 2.4 m).
Recommended mounting height is 7.5 feet (2.3 m).
Remove the cover. Insert a flathead screwdriver into the locking
tab hole at the bottom front of the detector. Pull the cover up and
forward.
Wire
Entrances
Corner Mount
Knockout (4)
Bracket Mount
Knockout
Vertical Adjust
Screw Mount
Surface Mount
Knockout (2)
Wire
Entrances
Cover Tab and
Locking Screw Hole
Remove the circuit board from the base. Loosen the Vertical
Adjust Screw and slide the circuit board down, then out.
Break away the appropriate thin-wall wire entrance and mounting
hole coverings in the base.
Terminal
Strip
_ +
NO C NC T
Tri-color
LED
Motion Monitor
and Anti-Mask
Selection Pins
LED
On
On/Off
Off
Pins
30
1
Memory
*
Off
Jumper
INT
STD
Vertical
Adjust
Screw
*= Cut only if using the Memory
Microwave Noise Voltage Pins
or 1 Day Motion Monitor features.
Walk test before cutting.
T M TR
Look Down
Lens
Look Down
Mask
PIR
Sensitivity
Selection Pins
- 4°
Vertical Adjust
- 8°
Scale
Microwave
Range Adjust
MW
Trouble
Memory
PIR Noise
Voltage Pins

Advertisement

loading

Summary of Contents for Bosch TriTech DS950 Series

  • Page 1 1 Day Motion Monitor features. • Reading Bosch Security Systems, Inc. Product Date Codes Walk test before cutting. For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/ • Remove the circuit board from the base. Loosen the Vertical datecodes/.
  • Page 2 When the switched voltage is removed from Terminal 8, the motion monitor timer will continue to count down until motion is detected. Page 2 © 2011 Bosch Security Systems, Inc. DS950 Series Installation Instructions...
  • Page 3 Moving the board up will angle the pattern downward. off these sources as well as during the three minute interval). • Tighten the screw snug when positioning is completed. DS950 Series Installation Instructions © 2011 Bosch Security Systems, Inc. Page 3...
  • Page 4 11.0 Coverage Pattern • Connect the meter to the Microwave (μw) Noise Voltage Pins. The DS950 has a standard broad coverage pattern or an optional long-range coverage pattern. The protected coverage area is where • With no target motion in the pattern, read the voltage. The the microwave and PIR patterns overlap.