Tests; Troubleshooting Test - Electrolux EWFLS70JIW Wiring Diagram

Wiring diagram (all languages)
Table of Contents

Advertisement

Available languages

Available languages

Test
Test 1
1. Is the incoming water flow normal?
2. Are the incoming water faucets turned on?
3. Is the incoming water pressure above (20) psi.
4. Does the fill water continue to enter the washer?
5. Remove power from the washer. Did the water fill stop?
6. Replace the pressure sensor.
7. Replace the main control board.
Test 2
1. Is the washer leaking water?
2. Is there an air leak in the air bell system?
3. Replace the pressure sensor.
4. Replace the main control board.
Test 3
1. Check the drain hose for restrictions.
2. Start the washer and check for 120 VAC at the drain
pump.
Test 4
Inspect the wiring between the pressure sensor and the
main control board.
1. Is the water level above 4.5 inches?
Test 5
2. Does water enter the washer continuously?
3. Remove power from washer. Does the water stop
coming in?
4. Replace the pressure sensor switch. Did this correct
the problem?
1. Is the loading door closed?
Test 6
2. Can you hear the lock attempt to close?
3. Check wire connection between door lock and main
control board
1. Disconnect the plug from the drive motor and measure
Test 7
the resistance pins 4 & 5 in the motor.
Check
Test
Yes. Go to step (4).
No. Go to step (2)
No. Turn water faucets on.
Yes. Go to step (3).
No. Have customer correct pressure problem.
Yes. Check for kinked or blocked incoming water
hoses, clean the incoming water screens. If problem
still remains, replace the water inlet valve assembly.
Yes. Go to step (5).
No. Go to step (6)
Yes. Go to step (6)
No. Replace the inlet valve assembly.Pressure
switch checks good. Go to step (7).Pressure
switch checks bad. Replace the pressure switch.
If this did not correct the problem, go to step 7.
Yes. Correct water leak.
No. Go to step (2)
Yes. Correct the air leak problem.
No. Go to step (3)
If this did not correct the problem, Go to step (4)
Restriction. Correct problem.
No restriction. Go to step (2).
Zero. Check the wiring. If wiring good, replace the
main control board.120 VAC. Remove the pump and
check for blockage. If blocked, remove the
restriction, if not, replace the pump.
Defective wiring. Correct wiring.Good wiring.
Replace the pressure sensor. If this does not correct
the problem, replace the main control board.
Yes. Go to step (2).
No. Go to step (4).
Yes. Go to step (3).
No. Check Air Trap for clog, if not replace the main
control board.
No. Replace the water valve assembly.
Yes. Check wiring to valve assembly for shorts. If
wiring is good, replace the main control board.
Yes. Problem solved.
No. Replace the main control board.
No. Close the door.
Yes. Go the step (2).
Yes. Check the door strike. If good, replace the door
switch.
No. Go the step (3)
If good, replace the door lock. If problem is not
corrected, replace the main control board.
If the reading is between 105 & 130 Ohms, replace
the motor control board.If the meter reads other than
between 105 & 130 Ohms, replace the motor.
4
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewfls70jmbEwfls70jrrEwfls70jss

Table of Contents