Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer Installation Instructions Manual
Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer Installation Instructions Manual

Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer Installation Instructions Manual

29" (73.7cm) gas dryer
Hide thumbs Also See for 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer:
Table of Contents

Advertisement

Available languages

Available languages

29" (73.7 CM) GAS DRYER INSTALLATION
INSTRUCTIONS
INSTRUCCIONES DE INSTALACION PARA
LA SECADORA A GAS DE 29" (73.7 CM)
Table ofContents
DRYER SAFETY ....................................... 1
Tools and Parts...................................... 4
Location Requirements
........................ 4
Electrical Requirements ......................... 5
Gas Supply Requirements ..................... 6
Venting Requirements ........................... 7
Plan Vent System .................................. 8
Install Vent System ................................ 9
Install Leveling Legs .............................. 9
Level Dryer ............................................. 9
Make Gas Connection ........................... 9
Connect Vent ....................................... 10
Reverse Door Swing (Optional) ........... 10
Complete Installation ........................... 11
SERVICE NUMBERS ....... BACK COVER
indice
Herramientas y piezas ......................... 15
Requisitos de ubicaci6n ...................... 15
Requisitos electricos ........................... 16
Requisitos del suministro de gas ........ 17
Requisitos de ventilaci6n .................... 18
Planificaci6n del sistema
de ventilaci6n ....................................... 19
Instalaci6n del sistema
de ventilaci6n ....................................... 20
Instalaci6n de las patas niveladoras ...21
Nivelaci6n de la secadora ................... 21
Conexi6n del suministro de gas .......... 21
Conexi6n del ducto de escape ........... 22
C6mo invertir el cierre de
la puerta (opcional) .............................. 22
Complete la instalaci6n ....................... 23
NUMEROS DE
SERVlCIO ................. CONTRAPORTADA
DRYER SAFETY
Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE iNSTRUCTiONS
8533591B

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer

  • Page 1: Table Of Contents

    29" (73.7 CM) GAS DRYER INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION PARA LA SECADORA A GAS DE 29" (73.7 CM) indice Table ofContents DRYER SAFETY ........1 SEGURIDAD DE LA SECADORA ..12 INSTALLATION INSTRUCTIONS .... 4 INSTRUCCIONES DE INSTALACION ..15 Tools and Parts........
  • Page 2 WARNING Clothes dryer installation must be performed by a qualified installer. install the clothes dryer according to the manufacturer's instructions and local codes. Do not install a clothes dryer with flexible plastic venting materials or flexible metal (foil type) duct. if flexible metal duct is installed, it must be of a specific...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following: Read all instructions before using the dryer. Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Do not place items exposed to cooking...
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. • 8" or 10" pipe wrench • Level • 8" or 10" adjustable • Vent clamps wrench (for gas connections) •...
  • Page 5 Dryer D imensions Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home 151/4" 223/4 '' Construction and Safety Standard, Title 24 CFR, Part 3280 43W'/J [---- , -l(387 mr.) ,, i I E-------,-__(57--8 r.m) (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
  • Page 6 An individual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The shut off valve location should be easy to reach for opening and closing. A.
  • Page 7 Flexible metal vent must be fully extended and supported when the dryer is in its final location. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. Do not install flexible metal vent in enclosed walls, ceilings, or floors.
  • Page 8 • Donotuse anexhaust hood withamagnetic latch. Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. improper venting can cause moisture and lint to collect Refer to the manufacturer's instructions.
  • Page 9: Connect Vent

    Examine leveling legs, find diamond marking. Determine vent length and elbows needed for best drying performance • Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use. Screw legs into leg holes by hand. Use a wrench to finish NOTE: Do not use vent runs longer than those specified in turning legs until diamond marking is no longer visible.
  • Page 10 A combination of pipe fittings must be used to connect the dryer to the existing gas line. Shown is a recommended connection. Your connection may be different, according to the supply line type, size, and location. You can change your door swing from a right-side opening to a left-side opening, if desired.
  • Page 11: Level Dryer

    10. Remove door strike plug (B). Insert the door strike you Reversible Super Wide Side-Swing Door removed in Step 8 into hole and secure with screw. Insert door strike plug into original door strike hole and secure with screw. 11. Close door and check that door strike aligns with door catch (C).
  • Page 12: Seguridad De La Secadora

    INSTRUCCIONES DE INSTALACION PARA LA SECADORA A GAS DE 29" (73.7 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demos es muy importante, Hemos incluido muchos mensajes importantes de seguridad en este manual yen su electrodomestico. Lea y obedezca siempre todos los mensajes de seguridad.
  • Page 13 ADVERTENCIA: Para su seguridad, la informaci6n en este manual debe ser observada para minimizar el riesgo de incendio o explosi6n, o para prevenir dafios a propiedades, heridas o la muerte. - No almacene o use gasolina u otros liquidos y vapores inflamables cerca de _ste u otro aparato...
  • Page 14 INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA: A fin de reducir el riesgo de incendio, descarga el6ctrica o de daSo alas personas que usen la secadora, deben seguirse las precauciones bAsicas, incluidas las siguientes: Lea todas las instrucciones antes de usar la secadora. No repare o reemplace ninguna pieza de la secadora ni trate de repararla a menos que esto se recomiende No coloque los objetos expuestos...
  • Page 15: Instrucciones De Instalacion

    INSTRUCCIONES DE INSTALACION ReQna las herramientas y piezas necesarias antes de comenzar la instalaci6n. Lea y siga las instrucciones provistas con cualquiera de las herramientas enlistadas aqu[. • Llave para tubos de • Llave para tuercas de 1/4" 8" 6 10" o Ilave de cubo •...
  • Page 16 Dimensiones de la secadora Requisitos de instalacibn adicionales para las casas rodantes Esta secadora es apropiada para instalaciones en casas rodantes. La instalaci6n debe ajustarse al Estandar de seguridad 433/8 " ' . y construcci6n de casas fabricadas, Titulo 24 CFR, Parte 3280 151/41_1m } 433/811 223/4 II...
  • Page 17 Tipo de gas INSTRUCClONES PARA LA CONEXION A TIERRA Gas natural: m Para la conexi6n de una secadora mediante cable el6ctrico conectado a tierra: Esta secadora esta equipada para uso con gas natural. Su Esta secadora debe estar conectada a tierra. En el caso de diseSo esta certificado por la CSA Internacional para gases LP (de propano o butano) con la conversi6n apropiada.
  • Page 18: Conexi6N Del Suministro De Gas

    Requisitos para la conexi6n del suministro de gas • Use un codo y un accesorio adaptador abocinado NPT de 3/8" por 3/8" entre el conector de gas flexible y el tubo de gas de la secadora, para evitar que se doblen. •...
  • Page 19: De Ventilaci6N

    • Serecomienda elducto deescape d emetal rigido para evitar Una capota de ventilaci6n debe tapar el ducto de escape queseaplaste o setuerza. para evitar el ingreso de roedores e insectos a la casa. Ducto de escape de metal flexible La capota de ventilaci6n debe estar por Io menos a 12"...
  • Page 20 Doble el ducto gradualmente para evitar torceduras. • Instalaciones alternas para espacios limitados Los sistemas de ventilaci6n vienen en una amplia gama. • Use la menor cantidad posible de vueltas de 90 °. Seleccione el tipo mas apropiado para su instalaci6n. A continuaci6n se ilustran dos tipos de instalaci6n para Determinaci6n de la Iongitud del ducto de escape...
  • Page 21 Si la secadora no esta nivelada, apuntale la secadora, usando un bloque de madera. Use una Ilave de tuercas para regular las patas hacia arriba o hacia abajo y verifique nuevamente si la secadora esta nivelada. Peligro de Peso Excesivo Quite la tapa roja del tubo de gas.
  • Page 22: Conexi6N Del Ducto De Escape

    Introduzca los tornillos en los agujeros inferiores en el lado izquierdo de la carcasa. Atornillelos por la mitad. Coloque ©o de duct;o la puerta de tal forma que el extremo grande de la ranura de la bisagra, este encima de los tornillos. Deslice la puerta 1.
  • Page 23: Nivelaci6N De La Secadora

    Fije las bisagras de la puerta a la puerta de la secadora de 4. Verifique que la secadora este esta nivelada. Vea "Nivelaci6n de la secadora". manera que el orificio mas grande quede en la parte inferior de la bisagra. 8.
  • Page 24 Your Home For troubleshooting, product manuals and expert advice: managemyiife www.managemylife.com For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself.

Table of Contents