24-inch wide laundry center washer-gas dryer

Advertisement

MINIMUM
INSTALLATION
SPACING
• The installation spacing (shown below)
is in inches and is the minimum allowable.
• Additional spacing should be considered
for ease of installation and servicing.
• If closet door is installed, the minimum
air openings
in top and bottom are
required. Louvered doors with equivalent
air openings
in top and bottom are
acceptable.
° Recessed area and closet installations
require a 6-inch minimum clearance
above the laundry center.
° All installations
must be exhausted
outside. Use at least the minimum
dimensions
indicated.
0o_,oO
**48 sq. in.-
minimum
ventilation
area
#
**24 sq. in.
j,
_,.._ minimum-
__
._.[
ventilation
3"
,.. _
_..
area
-'_1"'
min J-_.
271/4"-_
I_-
**'51/2
"
(oooR
.oT show.)
ioooR
s.ow.)
(.oo w..
* Additional c learances forwall, doorandfloor moldings mayberequired.
** Opening isminimumfor closetdoor.Louvered doerwithequivalent a ir openings
isacceptable.
*** Additional s paceis needed whenexternal e xhaust e lbowis used,Canbe0"clearance
whenhouseexhausting is linedupdirectlywith dryerexhaust.
18