Hydrostatic Release Unit (Hru) - ACR Electronics GLOBAL FIX - REV G Product Support Manual

Emergency position indicating radio beacon
Table of Contents

Advertisement

4.3

Hydrostatic Release Unit (HRU)

The ACR HydroFix™ HRU has an expiration date of 2 years from the date of installation or 3 years from the
date manufactured, whichever comes first. Upon installing your beacon or new HRU, permanently scratch
the new expiration date on the HRU date calendar (as seen below).
Figure 1 HRU Date Calendar
The hydrostatic release can be replaced by removing the beacon from the bracket. Firmly press down on the
spring at the bottom of the shelter, then slide the hydrostatic release assembly out of the keyed opening on the
spring and mounting bracket. Discard the old HRU. Check the date manufactured on the bottom of the new
HRU and insert the new hydrostatic release assembly in place by engaging it to the opening of the ejection
spring and case. When replacing the HRU, ACR requires that you do not reuse any parts from the previous
HRU. Failure to replace the entire assembly can cause the bracket to malfunction. Always use original ACR
replacement parts (Replacement kit P/N 9490). Use of unauthorized replacement parts will void your warranty
and may cause the bracket to malfunction. Place the beacon into the mounting bracket, (lanyard facing
inward), and replace cover, securing in place with the cotter pin going through the hydrostatic release rod.
Date of Installation Example:
Date of installation of New HRU or First Installation of
EPIRB including new HRU: August 1, 2007.
This unit will need to be replaced in August of 2009.
Scratch off "AUG 8" and "2006" on the HRU date calendar
Date of Manufacture Example:
On the bottom of the HRU a date of manufacture is pin
stamped: 0806.
This unit will need to be replaced in 0809. Scratch off "AUG
8" and "2009" on the HRU date calendar
5
Y1-03-0157-2 Rev. G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rlb-35

Table of Contents