Brother HL 2060 - B/W Laser Printer Service Manual page 97

Service manual
Table of Contents

Advertisement

M-12
"55 HIGH VOL MALF" is displayed (Faulty output from the H.V.P.S. ASSY)
Possible cause
Step
Main PCB
1
HV harness
2
High-voltage
power supply
PCB
Check
When a test print is carried out, is the voltage
of the each pin in the main PCB connector P6
turned on and off as the below list?
Pin No.
1
2 3
6
7 8 9
2 3
7 8 9
3
4 5
8 9
10
4 5
9
10
5
6
7
11 12 13 14
16
18 19 20
17
7 8
12 13 14 15
18 19 20
17
8 9
10
13 14 15
18 19 20
9
10
14 15
10
15
11 12 13 14 15
16 17 18 19 20
12 13 14 15
13 14 15
18 19 20
14 15
15
16 17 18 19 20
Is the voltage of the each pin of the high-
voltage power supply PCB connector P2
turned on and off?
Signal name
Voltage
(reference
value)
4 5
/HV1AC
0V
5.8V
10
4 5
/HV1DC
0V
10.0V
10
/DBAC
0V
6.3V
/DBDC
0V
9.8V
DNSTY
1.0 ~ 4.0V
/HVT1
8
9
10
0V
15
23.0V
9
/HVT2
0V
10
17.6V
/HVT3
0V
10.0V
HVT4
0.2 ~ 5.0V
HVTFB
0.2 ~ 5.0V
TONER1
0.0 ~ 3.5V
0V
0V
TONER2
2.0 ~ 4.5V
24VRET
0V
24V
24V
HVHALFN
0.0 ~ 10.0V
VI-15
Result
Remedy
No
Replace the main PCB
assy.
Remarks
Default: 1.9V
No
Replace the HV harness.
Yes
Replace the high-voltage
power supply PCB assy.

Advertisement