IBM 8682 - Eserver xSeries 350 Hardware Maintenance Manual page 117

Hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
217-XXX-004
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
217-XXX-005
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
264-XXX-0NN
(NN = SCSI ID of failing Tape Drive)
264-XXX-999
(Errors on multiple tape drives, see error
text for more info)
301-XXX-000
(Failed Keyboard test)
405-XXX-000
(Failed Ethernet test on controller on the
System Board)
405-XXX-00N
(Failed Ethernet test on adapter in PCI
slot N)
415-XXX-000
(Failed Modem test)
FRU/Action
1. Fixed Disk 5
1. Fixed Disk 6
1. Tape Cartridge, if user executed the Read/Write Tape Drive test
(XXX = 256)
2. SCSI or power cable connected to the tape drive with SCSI ID NN
3. Tape drive with SCSI ID NN – refer to Help and Service Information
appendix of tape drive's User Guide.
4. System Board or SCSI Controller – run SCSI Controller diagnostic to
determine of SCSI bus is functioning properly.
1. See error messages/text in the PC Doctor error log for detailed
information on each individual tape drive error.
1. Keyboard
1. Verify that Ethernet is not disabled in BIOS.
2. System Board
1. Adapter in PCI slot N.
2. System Board
1. Cable
2. Modem
3. System Board
107