White Balance Adjustment - Zenith P50W38 Service Manual

Pv155 series
Table of Contents

Advertisement

2) After turning the RV401, voltage of D.M.M adjustment as
same as Vs voltage which on the label of the PCB Right/Top.
(Deviation : ±0.5V)
P805
P805
P805
Va
Va
Va
GND
GND
GND
NC
NC
NC
Vs
Vs
Vs
P804
P804
P804
DMM
DMM
+ - -
+ -
<Fig 1> Connection Diagram of Power Adjustment for Measuring

6. White Balance Adjustment

6-1. Required Equipment
Color analyzer (CA-100 or same product)
6-2. Connection Diagram of Equipment for
Measuring
(Manual Adjustment)
R-L 70
G-L 70
R-M 128
G-M 128
High Light
R-H 216
G-H 216
216 Gray Level
105~115Cd/§‡
<Fig 2> Connection Diagram of Manual Adjustment(High Light)
ADJUSTMENT INSTRUCTIONS
RV401
RV401
RV401
Vs ADJ
Vs ADJ
Vs ADJ
RV601
RV601
RV601
Va ADJ
Va ADJ
Va ADJ
COLOR
ANALYZER
TYPE;CA-100
RGB Signal Input
PDP MONITOR
MSPG-2100 or
MSTG-5200
6-3. White Balance Adjustment
Operate the Zero-calibration of the CA-100, then stick sensor
O
to PDP module surface when you make adjustment.
For manual adjustment, it is also possible by the following
O
sequence.
(1) Select WHITE PATTERN of HEAT RUN mode by pressing
POWER ON KEY on service remote control then
operate HEAT RUN more than 15 minute.
(2) Supply 216Gray Level, 50% size length and breadth signal to
RGB input. (Refer to Fig 2)
(3) W/B adjustment must be adjusted only High Light and then
save the adjustment value with Y Key.
(4) To adjust High Light, stick sensor to 216 Gray Level (or 105-
115 Cd/m
and press T, U on R/C in adjustment mode to select R-L or G-
L, press VOL +, - Key and adjust it until color coordination
becomes as below.
X: 0.275±0.003, Y: 0.280±0.003
Color temperature: 11,500°K±500°K
(5) Exit adjustment mode using Y Key.
6-4. RS-232C Communication Protocol
& Transmission Parameter
(1) Communication Parameter
1) Communication Protocol & Transmission Parameter
:
Communication Parameter
- Data Length: 8bit
- Parity: none
- Stop bit: 1bit
- Band Rate: 115200bps(UART)
- Communication code: ASCII code
[
2) Transmission $ Receiving Protocol
Transmission[Command1][Command2][][Set ID][][Data][Cr]
* [Command1]: First command to control PDP Monitor (j or
* [Command2]: Second command to control PDP Monitor
* [Set ID]: You can adjust the set ID to choose desired
Window
[
* [Data] : To transmit command data.
[
- 17 -
2
) Pattern, press ADJ Key on R/C for adjustment
Using Crossed(reverse) Cabel
k)
(a,b,c,....)
monitor ID number in special menu. Adjustment range
is 1 ~ 99. When selecting Set ID '0', every connected
set is controlled.
Set ID is indicated as decimal (1~99) on menu and as
Hexa decimal (0x0~0x63) on transmission/receiving
protocol.
Transmit 'FF' data to read status of command.