Specifications - KUSSMAUL AUTO CHARGE 091-127 Series Instruction Manual

3 step automatic battery charger
Table of Contents

Advertisement

Specifications

Input Power:& Fuse: See Chart
Output Power: See Chart
Charge Indicator: See Chart
Mode Indicators: Battery Fault, Time-out, Bulk Charge, Finish Charge, and Battery Charged
Recommended Battery Size: See Chart
Weight: 65 pounds
Temperature Compensation: Add suffix "TC" to Model Number shown in Table below
Output Current Select: Add suffix "HL" to Model Number for selectable output current levels.
Under Voltage: Add suffix "UV" to Model Number for Under Voltage signaling option.
Fifty (50) Hz Operation: 230VAC input power operation only. Add "/50" as suffix to 230
Model Number Composition:
Model Number
091-127-XXX-YY
091-127-12-80
115 Volts 60 Hz, 20 Amps
091-127-24-40
115 Volts 60 Hz, 20 Amps
091-127-32-30
115 Volts 60 Hz, 20 Amps
091-127-36-27
115 Volts 60 Hz, 20 Amps
091-127-48-20
115 Volts 60 Hz, 20 Amps
091-127-72-15
115 Volts 60 Hz, 20 Amps
091-127-96-12
115 Volts 60 Hz, 20 Amps
091-127-120-10
115 Volts 60 Hz, 20 Amps
091-127-144-8
115 Volts 60 Hz, 20 Amps
091-127-12-80-230
230 Volts 60 Hz, 10 Amps
091-127-24-40-230
230 Volts 60 Hz, 10 Amps
091-127-32-30-230
230 Volts 60 Hz, 10 Amps
091-127-36-27-230
230 Volts 60 Hz, 10 Amps
091-127-48-20-230
230 Volts 60 Hz, 10 Amps
091-127-72-15-230
230 Volts 60 Hz, 10 Amps
091-127-96-12-230
230 Volts 60 Hz, 10 Amps
091-127-120-10-230
230 Volts 60 Hz, 10 Amps
091-127-144-8-230
230 Volts 60 Hz, 10 Amps
in Model Number for 50Hz operation. Example: 091-127-XXX-YY-230/50.
091-127-XXX-YY-ZZZ-WW
Input Power
Input Fuse
VAC, Freq,, Current
Amps, Type
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
25 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
15 Amp Slow Blow
Options: TC, HL, UV
Input: Omit for 115VAC 60Hz
230 for 230VAC 60Hz
230/50 for 230VAC 50Hz
Output Amperes
Output Volts, DC
Output
Charge
XXX Volts, YY Amps
Indicator
12 Volts, 80 Amps
100 Ampere
24 Volts, 40 Amps
50 Ampere
32 Volts, 30 Amps
50 Ampere
36 Volts, 27 Amps
50 Ampere
48 Volts, 20 Amps
25 Ampere
72 Volts, 15 Amps
25 Ampere
96 Volts, 12 Amps
25 Ampere
120 Volts, 10 Amps
25 Ampere
144 Volts, 8 Amps
25 Ampere
12 Volts, 80 Amps
100 Ampere
24 Volts, 40 Amps
50 Ampere
32 Volts, 30 Amps
50 Ampere
36 Volts, 27 Amps
50 Ampere
48 Volts, 20 Amps
25 Ampere
72 Volts, 15 Amps
25 Ampere
96 Volts, 12 Amps
25 Ampere
120 Volts, 10 Amps
25 Ampere
144 Volts, 8 Amps
25 Ampere
Recommended
Battery Size
300 to 600 ampere-hours
150 to 300 ampere-hours
110 to 220 ampere-hours
100 to 200 ampere-hours
75 to 150 ampere-hours
50 to 100 ampere-hours
45 to 90 ampere hours
40 to 80 ampere hours
40 to 80 ampere hours
300 to 600 ampere-hours
150 to 300 ampere-hours
110 to 220 ampere-hours
100 to 200 ampere-hours
75 to 150 ampere-hours
50 to 100 ampere-hours
45 to 90 ampere hours
40 to 80 ampere hours
30 to 60 ampere hours

Advertisement