Sampling Analog Signals
Input
On the SampleMode page, youÕll set the conditions for your sample recording. Depending on
the input type you select, a different set of parameters will appear on this page. When youÕve
selected analog input, the page appears as in the diagram below. The differences between analog
and digital sampling are discussed in the section called Sampling Digital Signals on page 14-8.
SampleMode||Samples:131072K|Channel=2|||
Sample: None||| |||||||||||||||||||Src:Ext
Input|: Analog| ||Time:1s||||||||||Mon:Off
Gain||:0|dB|||||||| | ||||||||||||||||||||
Rate||:48.0KHz||||| L ||||||||||||||||||||
Mode||:Stereo|||||| R ||||||||||||||||||||
Thresh : Off||| | ||-dB| 6 0||40|| *|16|*|8|4|0
Record | |Auto| | Timer| | Preview ||||||||||||
The digital meters at the lower right of the display give a good indication of your sample level.
When you send a signal from your sample source, you should see the meters respond.
Src
The possible values for the Src parameter are Internal ( Int ) or External ( Ext ). Choose a value of
Ext when you want to sample the signal from an external source thatÕs connected to one of the
K2600Õs sampling inputs. Use a value of Int if you want to sample the K2600Õs own output.
Gain
The meters are calibrated in -dB units. A level of 0 dB indicates the maximum signal without
clipping. The sample will be free of clipping as long as the meter levels donÕt exceed 0 dB. For
optimum results, you should adjust the K2600Õs Gain parameter (or the gain from your sample
source) so that the signal stays below 0 dB. Otherwise, the signal will be clipped, causing the
loss of sample data, and usually resulting in audible distortion of the resulting sample. A few
clips (fewer than 100) may not cause any appreciable distortion. YouÕll get the best signal-to-
noise ratio with meter levels as close to 0 dB as possible, although youÕll Þnd that samples with
maximum meter readings as low as -12 dB can sound remarkably noise-free.
The relatively slow LCD output of the meter levels cannot show every peak in the incoming
signal. Therefore, you wonÕt necessarily see every transient in every sample you take. You will
be able to see any transient that is clipped, however, since whenever a clip occurs, the K2600 will
display the word ÒCLIPÓ above the meters, and will ßash the Master-mode LED. It will also give
you the number of clips in each sample before you save it.
Rate
After youÕve set your levels, you need to select the sample rate. You have four rates to choose
from. The tradeoffs that determine your best sampling rate are frequency response and storage
requirements. Higher sample rates capture more frequency content from your samples, but take
up more memory. Lower rates give you more sample time, but donÕt give the same frequency
response as higher rates. Rates of 29.4 or 32 KHz yield a ßat response up to about 14 and 15 KHz,
respectively. 44.1 and 48 KHz yield a ßat response up to 20 KHz, which is the upper limit of
audibility for most humans. The lower rates may be adequate for most sounds, since many
sounds have little content above 15 KHz. Sounds with a great deal of high-frequency content,
such as cymbals, should probably be sampled at the higher rates. You can save memory by
using lower sample rates for sounds without much high-frequency contentÑacoustic or electric
bass, for example.