Download Print this page

Kurzweil K2500 - PERFORMANCE GUIDE REV F PART NUMBER 910252 CHAP 6 Manual page 3

Control sources

Advertisement

exceptions to this rule, which have to do with global control source parameters. Globals affect
every note in each program's layer(s). Consequently they can't use local control sources as their
values, since local control sources affect each note independently.
Four of the control source parameters are always global: the Enable parameter on the LAYER
page (Program Editor), and the three control source parameters on the EFFECT page, (Program
Editor). When programming these parameters, you'll see the Main Control Source list minus
the three special MIDI control sources, minus the following local control sources:
Note St
Key St
KeyNum
BKeyNum
AttVel
InvAVel
PPress
BPPress
RelVel
Bi-AVel
VTRIG1
VTRIG2
RandV1
RandV2
ASR1
LFO1
FUN1
FUN3
Loop St
PB Rate
AtkSt
Rel St
Finally, if you've turned on the Globals parameter on the COMMON page in the Program
Editor, the available values for GLFO2, and the values for GASR2's trigger will lack the local
control sources listed above, as well as the three special MIDI control sources and the FUN
constants. The available values for GFUN2 and GFUN4 will exclude the same list of local
control sources, but will include the FUN constants.
Control Sources
6-3

Advertisement

loading

This manual is also suitable for:

K2500