Dimension One Spas Dynamic Massage Sequencer Owner's Manual

Dimension One Spas Dynamic Massage Sequencer Owner's Manual

Export version
Table of Contents

Advertisement

i

Advertisement

Table of Contents
loading

Summary of Contents for Dimension One Spas Dynamic Massage Sequencer

  • Page 2 2002 Dimension One Spas Export Owner’s Manual...
  • Page 3: Table Of Contents

    2002 Dimension One Spas Export Owner’s Manual IMPORTANT SAFETY INSTRUCTIONS ... 1 HYPERTHERMIA... 2 DO’S AND DON’TS ... 3 WARNING SIGNS... 4 HOT TUB FEATURES... 5 ADDITIONAL FEATURES FOR THE CHAIRMAN, CHAIRMAN II, DIPLOMAT, CALIFORNIAN, NAUTILUS, AURORA XLT, AURORA II, CALIENTE HP, AND TRIAD II... 5 ADDITIONAL FEATURES FOR THE ARENA, AURORA HP, CALIENTE, AND TRIAD ...
  • Page 4 2002 Dimension One Spas Export Owner’s Manual Using the Scrolling Message Center ...16 Setting the Time... 16 Filter Cycle Start Time ... 16 Filter Cycle Duration ... 16 Number of Filter Cycles... 16 Pump Run Time... 17 Temperature Unit Selection... 17 Vision Cartridge ...
  • Page 5: Important Safety Instructions

    2002 Dimension One Spas Export Owner’s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY When installing and using this equipment, basic safety precautions should always be followed, including: Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children.
  • Page 6: Hyperthermia

    Warning Do not block air intakes located on the front left corner underneath the hot tub (the front right corner for the Chairman II and Triad II) and under the equipment access panel. Resulting malfunctions are not covered under warranty.
  • Page 7: Do's And Don'ts

    Do not use the spa under the influence of alcohol, narcotics, or other drugs. Use of the spa under these conditions may lead to serious consequences. Caution Always test the hot tub water temperature before entering the spa. Enter and exit the spa slowly. Wet surfaces can be very slippery. Caution Never bring any electrical appliances into or near the spa.
  • Page 8: Warning Signs

    2002 Dimension One Spas Export Owner’s Manual Warning Signs Each spa has been provided with a Warning Sign and an Important Notice label. This label outlines safety precautions. This sign should be permanently placed in a location that is visible to the spa user.
  • Page 9: Hot Tub Features

    The valves are adjustable and can be used to suit the bather’s taste. The valves may offer some resistance to operation when the hot tub pump is on. This is a normal condition, and is caused by the high rate of water flow and pressure that travels through the valves.
  • Page 10: Neckflex Jet Pillow

    Heater and Circulation Pump Control On all Dimension One Spas, when the water temperature is 1° F (0.55° C) below the set temperature the heater will turn on and remain on until the water temperature rises to 1° F (0.55° C) above the set temperature. To prevent the hot tub from overheating, the circulation pump turns off when the water temperature rises 2°...
  • Page 11: Operation

    Dimension One Spas has put every hot tub function within fingertip control. Temperature setting, jet power control, and the hot tub light are all spa-side accessible. That means you don’t have to get out of the hot tub to enjoy complete control of all hot tub functions. Safety is assured through design concepts and materials that meet or exceed CE rating.
  • Page 12 Dimension One Spas ICON (Logo) The time of day can be viewed by pushing the Dimension One Spas ICON logo on the far right of the control. If no other pad is pushed within 5 seconds, the display will revert to the hot tub water temperature reading.
  • Page 13: Digital Display Messages

    WATER. If this happens, remove the hot tub cover and allow the water to cool below 110° F (43.3° C). Reset the power to the spa by resetting the GFCI breaker. If the problem recurs, turn off all power to the hot tub and...
  • Page 14: Using The Programmable Digital Controller

    To initiate the programming sequence at any time, push and hold the Program Pad for 3 seconds. If, within 10 seconds, you do not proceed with the hot tub programming, the hot tub will automatically exit the programming sequence and revert to the pre-set factory default settings. To exit the programming sequence at any time, do not press any pad for 10 seconds.
  • Page 15: Temperature Unit Selection

    (degrees Celsius). Once the desired temperature unit is selected push the Program Pad to exit the programming mode. The time of day can be viewed by pushing the Dimension One Spas logo on the far right of the control. If no pad is pushed within 5 seconds, the display will revert to the hot tub water temperature reading.
  • Page 16: Top Side Control

    “HEATING TO _ _ _° F” until the hot tub reaches the set temperature. If the water reaches 2° F (- 16.6° C) (above the set temperature, the message “COOLING TO _ _ _ - CIRC PUMP &...
  • Page 17: Scrolling Message Center (Digital Display) Messages

    MESSAGE” will scroll from right to left on the bottom line of the display. To reset this message, push and hold the Dimension One Spas ICON (logo) located at the right hand side of the control for 3 seconds. 5. ENTER Pad This pad is used to exit any programming sequence at any time.
  • Page 18: Clean Filters

    THIS MESSAGE” will scroll from right to left on the bottom line of the display. To reset this message, push and hold the Dimension One Spas ICON (logo) pad located at the right hand side of the control for 3 seconds.
  • Page 19: Ice

    30 minutes after the pump(s) turn off regardless of the water temperature. Note The Dimension One Spas Scrolling Message Center will keep all programming for 40 years with no power supply and the time of day for 30 days. This battery back up will not provide power to heat or operate the hot tub.
  • Page 20: Using The Scrolling Message Center

    To initiate the programming sequence at any time, push and hold the Program pad for 3 seconds. If, within 10 seconds, you do not proceed with the hot tub programming, the hot tub will automatically exit the programming sequence and revert to the pre-set factory default settings.
  • Page 21: Pump Run Time

    The invert feature will flip the text on the Digital Display so it can be easily read from both inside and outside the hot tub. To invert the text, simply push the “ENTER” pad three times. To return the text to its original position, repeat this process - push the “ENTER”...
  • Page 22: Programming Unlock

    Dynamic Massage Sequencer for the Aurora XLT, Chairman II and the Triad II The Dynamic Massage Sequencer, Figure 5, is located in the Ultra Lounge of the models mentioned above. The sequencer directs a succession of 14 jets to six separate muscle groups.
  • Page 23 2002 Dimension One Spas Export Owner’s Manual Control 2. JETS Pad Operates the jet pump associated with the Massage Sequencer. Status Light illuminates when pump is on. 3. SPEED Pad The SPEED pad is used to change the time between each step in all sequences.
  • Page 24: Massage Zone Description

    2002 Dimension One Spas Export Owner’s Manual Massage Zone Description The Dimension One Spas Dynamic Massage Sequencer lets you enjoy a wide variety of massage patterns on the most critical muscle groups of-your body. You can choose six automatic jetting sequences, with six different zones, for a completely personalized hydrotherapy, see Figure 6.
  • Page 25: Operating The Dynamic Massage Sequencer

    2002 Dimension One Spas Export Owner’s Manual Zone 6 This zone is designed to massage the feet. There are two directional mini VCR jthat are water volume controllable, interchangeable with rotating jets and provide a narrowly focused massage pattern. Operating the Dynamic Massage Sequencer Push the JETS pad to turn on the spa pump.
  • Page 26 2002 Dimension One Spas Export Owner’s Manual 1. Location of Male Hose Fitting Figure 9 Male Hose Fitting Close the valve on the side of the hose bib and screw the cap onto the end of the hose bib. Check the pump unions, Figures 10 and 11, to be sure that they are tight to prevent the possibility of leakage in the equipment compartment.
  • Page 27 (handles fully extended). 10. Turn on the circuit breaker (not supplied by Dimension One Spas). Flashing dashed lines will appear for 30 seconds on the Digital Display followed by the current water temperature (flashing).
  • Page 28: Routine Equipment Maintenance

    Feature Filter Cleaning Before cleaning the filter element(s) place the spa in the “Standby” mode by pressing the Dimension One Spas ICON logo for 5 seconds. Your system is equipped with one or two top access filter cartridges. We recommend that you clean the filters every month as preventative maintenance.
  • Page 29: Surface Care - Ultralife And Granitex

    Dimension One Spas’ Water Line Cleaner. You may also use Dimension One Spas’ ph/Alkalinity Increaser or mild cleaners like Soft Scrub. Be sure to thoroughly rinse the shell. After cleaning, you will want to restore your hot tub shell’s original luster by using Dimension One Spas’ Poli-Gloss.
  • Page 30: Care For The Wood Spa Cabinet

    To protect your beautiful wood finish, re-stain it every 3-6 months with Dimension One Spas’ Redwood or Coastal Gray Stain, which serves as a good sealing agent for the wood. Please note that the cabinet is not warranted against reaction to natural weather conditions.
  • Page 31 2002 Dimension One Spas Export Owner’s Manual If your system has a Dynamic Jet Sequencer, please remove that access panel as well and loosen all unions on each of the sequencer valves. There are 6 sequencer valves, that means that you will have to loosen 12 unions.
  • Page 32: Spring Time Startup

    Always check your system after any power failure to ensure that it is operational. Draining and not operating your system disables this feature. Caution For additional information about winterizing your spa, please contact your local Authorized Dimension One Spas dealer.
  • Page 33: Warranty Service Information

    The warranty does not cover problems arising from misuse, abuse, or neglect, and it does not cover problems caused by improper installation or “perceived” problems caused by failure to read the hot tub owner’s manual. A service charge will be made if a service call is made for any of the following: Equipment failure due to improper/inadequate electrical service.
  • Page 34: Glossary Of Terms

    Free chlorine, bromine or iodine ions that are very strong oxidizers used to sanitize water. ICON Pad This is a pad accessed by pressing the Dimension One Spas Logo on the far right of the Top Side Control Panel. Jets Return the water into the spa from the equipment.
  • Page 35 Term Definition completely open during normal operations. (Available on Dimension One Spas only) Smart Heat optimizes heat recovery Smart Heat using the amperage that you have available. Along with computerized load sharing, that automatically recognizes the number of jet pumps in use, compares it with...
  • Page 36: Troubleshooting Guide

    Call for service Turn down the thermostat Call for service Call for service Fill hot tub to 1” (2.54 cm) to 2” (5.08 cm) above bottom of the tile line Corrective Action Check circuit breaker and/or GFCI No action required...
  • Page 37: Water System

    2002 Dimension One Spas Export Owner’s Manual Water System Symptom Problem Pulsating jets Water level too low No Jet Action, Jets are turned off or action is Diverter Valve poor turned Dirty Filter Air lock Gate valve closed Possible sensor errors The “Check...
  • Page 38 2002 Dimension One Spas Export Owner’s Manual...
  • Page 39 2002 Dimension One Spas Export Owner’s Manual...
  • Page 40 2002 Dimension One Spas Export Owner’s Manual...

Table of Contents