Kurzweil K2500 - PERFORMANCE GUIDE REV F PART NUMBER 910251 CHAP 15 Sampling Manual page 18

Sampling and sample editing
Table of Contents

Advertisement

Sampling and Sample Editing
Editing Samples
will be used when the Mod Wheel—or whatever control source you have set to send MWheel—
is above its halfway point).The Alt can be set before, after, or at the same point as the Start or
end.
If you set the Alt after the End, you can extend the play of looped samples. Normally, looped
samples will play through to the End, then will loop back to the Loop point, and continue
looping like this until the note is released, when they go into their normal release. If the Alt is
set after the End, looped samples will loop in the same way while notes are sustained. As soon
as you release the notes, however, the samples will play through to the Alt point before going
into release.
The Loop (L) parameter sets the beginning of the looped portion of the current sample.
Although you can adjust this parameter while you're on the TRIM page, you'll normally want
to adjust it while viewing the LOOP page, so you can see the loop transition points, enabling
you to create as smooth a loop as possible. The Loop can be set at any point before the End,
including before the Start and Alt. If you try to move it after the End, the End will be moved
with it.
The End (E) parameter sets the point at which the current sample will stop playback. Typically
you'll use this parameter to trim unwanted silence off the end of a sample, although you can
use it to shorten a sample as much as you want.
If you want to truncate a sample to save memory, there are two points to keep in mind. First, if
the Alt parameter is set before the Start, you won't save any memory by truncating the Start.
Likewise, you won't save memory by truncating the End if the Alt is set after the End. You
won't save memory by truncating a sample until you save the sample and exit the Sample
Editor.
You can also use the Truncate DSP function to automatically truncate your samples at a
specified noise floor. As with the TRIM page, you'll recover memory after saving the sample
and exiting the Sample Editor.
LOOP
The LOOP page features the same four parameters as the TRIM page, but the waveform
display is quite different. The best way to understand what you see on the LOOP page is to
switch back and forth between the TRIM and LOOP pages and study the waveform displays.
EditRamSample:LOOP|Zoom=1/256|||||||||||
S:2.530|||A:2.530|||L:4.267|||E:6.000|||
VVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVV
-6dB>|||||||||||||||||||||||||||||||||||
****************************************
||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||
<more|||MISC|||TRIM|||LOOP|||DSP|||more>
On the TRIM page you see the entire waveform—or as much of the waveform as your current
zoom setting allows. When you move to the LOOP page, you'll notice that the page is split into
two sections, left and right, divided by a vertical bar in the center. This bar is thicker than the
vertical lines representing the Start, Alt, Loop, and End points, and does not move when you
adjust any of these points.
15-18

Advertisement

Table of Contents
loading

This manual is also suitable for:

K2500

Table of Contents