Increasing The Security Level After Upgrading A Zenworks Server From Zenworks 7 Linux Management With Ir1 - Novell ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009 Installation Manual

Hide thumbs Also See for ZENWORKS LINUX MANAGEMENT 7.2 IR2 - INSTALLATION GUIDE 07-20-2009:
Table of Contents

Advertisement

2 Execute the
upgrade_bundle_name is the upgrade bundle in the catalog assigned to the managed device.
IMPORTANT: It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
rug ping
is 7.2.0. If you perform the
message. You can recover by stopping and restarting zmd. The
contain the
3 If the device does not have the X Window System installed:
3a In ZENworks Control Center, click the upgrade bundle.
3b Click the Details tab.
3c In the Packages panel, select the following packages:
novell-zenworks-x11vnc-0.6.1-2
novell-zenworks-zmd-gconfpolicyenforcers-7.2.1-0
novell-zenworks-tightvnc-1.2.9-6, zen-updater-7.2.1-0.1
3d Click Action > Set Freshen.
4 (Optional) If SLES 10 or SLED 10 are running on DELL server and the managed devices have
the default zmd agent installed, do the following if you want to collect the Dell inventory of the
devices:
4a In the Packages panel, select novell-zenworks-zmd-oem.
4b Click Action > Unset Freshen.
11.2 Increasing the Security Level After
Upgrading a ZENworks Server from ZENworks 7
Linux Management with IR1
If you upgrade a ZENworks Server from ZENworks 7 Linux Management with IR1 to ZENworks
7.2 Linux Management, the default PostgreSQL database security level requires authentication, but
you can optionally increase the security level of the database. In most corporate settings, the
PostgreSQL database resides on a corporate LAN with firewall protection. If you want to increase
the security level of the database, edit the
and subnet mask for the ZENworks Primary Server and for all ZENworks Secondary Servers as well
as for the local host. An unedited file has a series of zeroes in place of the IP addresses and subnet
masks; you replace the zeroes with the information for your primary and secondary ZENworks
servers.
If you upgrade from ZENworks 7 Linux Management - Dell* Edition, this process is not necessary.
See the PostgreSQL documentation for more information.
90
Novell ZENworks 7.2 Linux Management Installation Guide
/usr/bin/rug bin -y upgrade_bundle_name
command or refer to upgrade.log. The upgrade was successful if the version of zmd
rug ping
"Starting ZENworks Management Daemon..."
command prematurely, you receive an exception
/var/lib/pgsql/pg_hba.conf
command, where
rug ref
/tmp/zmd/upgrade.log
message in the last line.
file to add the IP address
must

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks linux management 7.2 ir2

Table of Contents