Novell ZENWORKS 10 CONFIGURATION MANAGEMENT SP3 - MIGRATION GUIDE 10.3 30-03-2010 Migration Manual page 93

Hide thumbs Also See for ZENWORKS 10 CONFIGURATION MANAGEMENT SP3 - MIGRATION GUIDE 10.3 30-03-2010:
Table of Contents

Advertisement

Action: Perform the following steps to migrate the application as an individual action
instead of an MSI:
1. Launch the Migration Utility.
2. Click the Migration Tool Settings icon, then click Application.
3. Select the Migrate distributions options as individual actions option.
4. Migrate the application that has the registry changes to the destination
Unable to migrate objects that should be uploaded to the content server
Explanation: While migrating objects that should be uploaded to the content server, the
Migration Utility might encounter an error resulting in the failure of migration.
Possible Cause: The Proxy enabled on the device that is hosting the Migration Utility might not
be configured to send data in chunks or establish a persistent connection with
the server while uploading files to the content server.
Action: Use the Web Client Configuration option to configure the settings for
uploading files to the content server and try migrating again. For more
information, see the
Possible Cause: The connection to the remote server might have failed.
Action: Ensure that the File Upload Http Port specified while logging in to the
migration destination zone is the same as the port configured on the ZENworks
Configuration Management server.
Unable to install the migrated Adobe MSI
Possible Cause: The Adobe* Flash* Player plug-in is installed on the device.
Action: Perform the following steps on the managed device before deploying the
bundle to the device:
1 Open the command prompt.
2 Navigate to the Flash Player plug-in installation directory. The default
3 Do the following to unlock the registry entries of the existing Flash files:
4 Deploy the bundle on the managed device.
zone. The application is migrated as a Windows Bundle with a Regedit
action.
Section B.1.8, "Web Client Configuration," on page
installation directory is
C:\WINDOWS\system32\Macromed\Flash
If the
uninstfl.exe
command:
uninstfl.exe -u
If a file with a name matching
NPFSW32_FlashUtil.exe,
command:
*FlashUtil.exe -uninstallUnlock -u
file is available, execute the following
*FlashUtil.exe
is available, execute the following
82.
.
, such as
Troubleshooting
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zenworks 10 configuration management sp3

Table of Contents