Figure 6. Hardware Block Diagram; Table 1. Jumper Description - Intel RES2SV240 Hardware User's Manual

Raid expander card
Table of Contents

Advertisement

s
Jumper
Description
J1 - J6
Internal mini SAS Port
Connectors, Ports 0-3, 4-7, 8-
11,12-15,16-19 and 20-23
J7 - J8
Discrete Fault LED header
J9
SGPIO connector
J10
Power connector
SFF8087 Internal
SFF8087 Internal
SAS/SATA
SAS/SATA
CONNECTOR
CONNECTOR
Ports 0-3
Ports 4-7
TX RX
TX RX
LSI*LSISAS2x24 24-Port SAS/SATA Expander Chip
12

Table 1. Jumper Description

Type
2x12 pin header
4-pin connector
RA 4-pin
connector
SFF8087 Internal
SFF8087 Internal
SAS/SATA
SAS/SATA
CONNECTOR
CONNECTOR
Ports 12-15
Ports 8-11
TX RX
TX RX

Figure 6. Hardware Block Diagram

Connection to SAS/SATA devices:
J1 = SAS port (0-3)
J2 = SAS port (4-7)
J3 = SAS port (8-11)
J4 = SAS port (12-15)
J5 = SAS port (16-20)
J6 = SAS port (20-23)
Connects to external, green or red LEDs that
indicate drive faults, two 2x12 headers can support
24 LEDs
SGPIO out-of-band enclosure management,
specifically to be used for Intel
non-expander SATA/SAS backplane
12V power input from remote power supply
SFF8087 Internal
SFF8087 Internal
SAS/SATA
SAS/SATA
CONNECTOR
CONNECTOR
Ports 16-19
Ports 20-23
TX RX
TX RX
Intel® RAID Expander Card RES2SV240 Hardware User's Guide
Comments
®
6-drive hot-swap
FLASH
LOCAL BUS
EEPROM
SGPIO
GPIOs
Connector