Installing Logs - Desa Comfort Glow S39NT Owner's Operation And Installation Manual

Comfort glow vent-free natural gas freestanding pedestal stove system owner's manual
Hide thumbs Also See for Comfort Glow S39NT:
Table of Contents

Advertisement

VENT-FREE NATURAL GAS PEDESTAL STOVE
INSTALLATION
Continued

INSTALLING LOGS

WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installation and
periodically thereafter, check to en-
sure that no flame comes in contact
with any log. With the heater set to
High, check to see if flames contact
any log. If so, reposition logs ac-
cording to the log installation in-
structions in this manual. Flames
contacting logs will create soot.
It is very important to install the logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
Place one-piece log set on grate to fit as
illustrated in Figure 10. Make sure log sits
flat on firebox floor (see Figure 9).
IMPORTANT: Make sure log does not cover
any burner ports (see Figure 10).
One Piece
Log Set
Firebox Floor
Figure 9 - Installing One-Piece Log Set
One Piece Log Set
Burner Ports
Figure 10 - Installing One-Piece Log set
(Top View)
For more information, visit www.desatech.com
INSTALLING OPTIONAL
BLOWER ACCESSORY
GA3750
Tools required: Phillips screwdriver
NOTICE: Shut off gas heater during
the following blower installation.
1. Remove 2 screws from rear tabs on top
trim. Pull trim forward to remove (see
Figure 11).
2. Remove top panel of stove by remov-
ing three screws from under top lip on
each side of stove (see Figure 11).
3. Facing front of stove, carefully slide top
panel forward until it is completely re-
moved from stove (see Figure 11).
4. Install one plastic bushing provided in
1
blower kit into the 1
/
2
rear of firebox floor. Access hole
through the rectangular opening in the
rear panel (see Figure 12).
5. Disconnect power cord wires from blower
motor (if connected) (see Figure 13).
6. Disconnect green ground wire from
blower housing (if connected) by re-
moving screw holding wire terminal
(see Figure 13).
7. Remove the two blower mounting
brackets from the rear panel by remov-
ing two screws each (see Figure 14).
Top Panel
Top
Trim
Figure 11 - Removing Stove Top Panel
Figure 12 - Installing Bushing
10
8. Attach the two mounting brackets to
blower housing using four screws pro-
vided in blower kit (2 for each bracket)
(see Figure 14). Tighten screws se-
curely. Place blower assembly tempo-
rarily on top of firebox.
9. Working from the rear of the stove,
place entire power cord, including
speed control housing, in lower control
compartment.
10. Route ends of 3-wire power cord up from
the lower control compartment through
the plastic bushing, then up to the upper
cavity of stove (see Figure 15, page 11).
11. Attach the terminal ends of the white
and black power cord wires to the ter-
minals on the blower motor (see Fig-
ure 12). Push firmly.
12. Attach the terminal end of the green
" hole in the left
power cord wire to the front tab of the
blower housing using screw provided
(see Figure 13).
White
Powercord
Wire
Black Powercord Wire
Screws
Figure 13 - Removing Wires from Blower
Blower
Screws
Figure 14 - Removing Blower Brackets
from Stove and Attaching to Blower
Screw
Green
Ground Wire
Screws
Blower
Bracket
Screws
Firebox Top
107434

Advertisement