Unpacking; Product Features; Air For Combustion And Ventilation - Desa 107434-01C.pdf Owner's Operation And Installation Manual

Vent-free natural gas freestanding pedestal stove system
Table of Contents

Advertisement

UNPACKING

4

PRODUCT FEATURES

Safety Pilot
Piezo Ignition System

AIR FOR COMBUSTION AND VENTILATION

Providing Adequate Ventilation
UNPACKING
1.
Remove top inner pack.
2.
Tilt carton so that stove is upright.
3.
Remove protective side packaging.
4.
Slide stove out of carton.
5.
Remove protective plastic wrap.
6.
Remove screen by lifting and then pulling forward.
7.
Remove log set by cutting plastic ties.
8.
Carefully unwrap log.
9.
Check for any shipping damage. If stove or log is damaged,
promptly inform dealer where you bought stove.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches,
batteries, or other sources to light heater.
AIR FOR COMBUSTION AND
VENTILATION
WARNING: This heater shall not be installed in a
confined space or unusually tight construction unless
provisions are provided for adequate combustion and
ventilation air. Read the following instructions to in-
sure proper fresh air for this and other fuel-burning
appliances in your home.
Today's homes are built more energy efficient than ever. New
materials, increased insulation, and new construction methods help
reduce heat loss in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out and the warm air
in. During heating months, home owners want their homes as
airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, heaters, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction
where:
a. walls and ceilings exposed to the outside atmosphere
have a continuous water vapor retarder with a rating
of one perm (6 x 10
openings gasketed or sealed and
b. weather stripping has been added on openable win-
dows and doors and
c. caulking or sealants are applied to areas such as
joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between
wall panels, at penetrations for plumbing, electrical,
and gas lines, and at other openings.
If your home meets all of the three criteria above, you
must provide additional fresh air. See Ventilation Air
From Outdoors , page 6 .
If your home does not meet all of the three criteria above,
proceed to Determining Fresh-Air Flow For Heater Loca-
tion, page 5 .
Confined and Unconfined Space
The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a
confined space as a space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m
of all appliances installed in that space and an unconfining space as
a space whose volume is not less than 50 cubic feet per 1,000 Btu per
3
hour (4.8 m
per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the
space in which the appliances are installed*, through openings not
furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
-11
2
kg per pa-sec-m
) or less with
3
per kw) of the aggregate input rating
107434-01C