Specifications; Technical Service; Service Hints; Replacement Parts - Desa RN30E-CAN Owner's Operation And Installation Manual

Blue flame vent free propane and natural gas greenhouse co2 generator owner's manual
Table of Contents

Advertisement

SPECIFICATIONS

Btu (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (inches of water)
Maximum
Minimum
Dimensions, Inches (H x W x D)
Appliance
Carton
Weight (pounds)
Appliance
Shipping
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International's Technical
Service Department at 1-800-323-5190.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• appliance will not produce maximum CO2
• (Propane Only) propane/LP gas supply
may be low
When Gas Quality Is Bad
• pilot will not stay lit
• burner will produce flames and soot
• appliance will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
105056
RP30E-CAN
RN30E-CAN
15,000/30,000
15,000/30,000
Propane/LP Only
Natural Only
Piezo
Piezo
8" W.C.
3" W.C.
14"
10.5"
11"
4"
23.5 x 25.9 x 8.0
23.5 x 25.9 x 8.0
26 x 27.75 x 9.63
26 x 27.75 x 9.63
30
30
35
35
ACCESSORIES
Purchase this CO2 generator accessory from
your local dealer. If they can not supply this
accessory contact DESA International's Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
MANUAL SHUT OFF VALVE -
GA5010
Manual shutoff valve with 1/8" NPT tap.
OWNER'S MANUAL
REPLACEMENT
PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product.
If they can't supply original replacement
part(s) contact DESA International's Tech-
nical Service Department at 1-800-323-
5190.
When calling, have ready
• your name
• your address
• model number of your CO2 generator
• how appliance was malfunctioning
• type of gas used (propane/LP or natural
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product.
If they can't supply original replacement
part(s) contact DESA International's Parts
Department at 1-800-972-7879 for referral
information.
When calling, have ready
• model number of your CO2 generator
• the replacement part number