INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the appliance will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 19
• turn appliance off (see To Turn Off Gas
to Appliance, page 10)
• see Troubleshooting, pages 12 through 14
Thermocouple
Figure 18 - Correct Pilot Flame Pattern
Thermocouple
Figure 19 - Incorrect Pilot Flame Pattern
105056
BURNER FLAME PATTERN
Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
heat shield height.
If burner flame pattern is incorrect, as shown
in Figure 21
• turn appliance off (see To Turn Off Gas
to Appliance, page 10).
• see Troubleshooting, pages 12 through 14
WARNING: If yellow tipping
occurs, your CO2 generator could
produce increased levels of car-
bon monoxide. If burner flame
pattern shows yellow tipping, fol-
low instructions at bottom of this
page.
Pilot Burner
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
appliance and burn causing brief
patches of orange flame.
Pilot Burner
1/2 HEAT SHIELD
HEIGHT
Figure 20 - Correct Burner Flame Pattern
Yellow
Tipping
1/2 HEAT SHIELD
HEIGHT
Figure 21 - Incorrect Burner Flame Pattern
OWNER'S MANUAL
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
Exterior
• Use a soft cloth dampened with a mild
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
11
WARNING: Turn off appliance
and let cool before cleaning.
CAUTION: You must keep con-
trol areas, burner, and circulating
air passageways of appliance
clean. Inspect these areas of ap-
pliance before each use. Have
CO2 generator inspected yearly
by a qualified service person. Ap-
pliance may need more frequent
cleaning due to excessive saw-
dust, cobwebs, etc.
small, soft bristled brush to clean.
to clean.
soap and water mixture. Wipe the cabi-
net to remove dust.