Operating Fireplace - Desa Vanguard VSGF28NTE Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) gas fireplace vsgf28nte, vsgf28pte
Table of Contents

Advertisement

OPERATING FIREPLACE

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don't
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a quali-
fied service technician to inspect the appli-
ance and to replace any part of the control
system and any gas control which has been
under water.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this fireplace with the fire-
place screen in place. Make sure
fireplace screen is installed be-
fore running fireplace.
113135-01A
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
1. STOP! Read the safety information, col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise
OFF position (see Figure 28).
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information, column 1. If you don't
smell gas, go to the next step.
5. Turn control knob counterclockwise
control knob for five (5) seconds (see Fig-
ure 28).
Note: If running fireplace for first time,
there will be air in gas line. You may need
to press in control knob for 30 seconds or
longer. This will allow air to bleed from the
gas system.
6. Continue pressing control knob in. Press
and release ignitor button. This will light
pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor but-
ton until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 18.
Figure 28 - Control Knob and Ignitor
www.desatech.com
to the PILOT position. Press in
Ignitor Button
Button Location
to the
Control
Knob
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vanguard vsgf28pte

Table of Contents