Desa TC36N Series Owner's Operation And Installation Manual page 14

Desa owner's operation and installation manual direct-vent fireplace tc36n,tc36p
Table of Contents

Advertisement

VENTING INSTALLATION INSTRUCTIONS
HORIZONTAL SYSTEM INSTALLATION
USING TWO 90° ELBOWS
The following configurations show the minimum
vertical rise requirements for a horizontal system
using two 90° elbows.
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1)
5' min.
2' max.
6' min.
4' max.
7' min.
6' max.
8' min.
8' max.
20' max.
8' max.
Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows
Venting with Two 90° Elbows
Vertical (V)
5' min.
6' min.
7' min.
8' min.
20' max.
Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows
14
Continued
Horizontal (H1) +
Horizontal (H2)
6' max.
12' max.
18' max.
20' max.
20' max.
Horizontal (H
) +
1
Horizontal (H
)
2
6' max.
12' max.
18' max.
20' max.
20' max.
with Termination at 90° with Fireplace
www.desatech.com
45° Elbow
45° Elbow
116192-01E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc36p seriesVtc36n seriesVtc36p series

Table of Contents