Desa LMFP33NR(A) Owner's Operation And Installation Manual page 20

Unvented (vent-free) gas fireplace
Hide thumbs Also See for LMFP33NR(A):
Table of Contents

Advertisement

OPERATING HEATER
Continued
LIGHTING
INSTRUCTIONS
WARNING
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across opening of fireplace.
• You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
Note: Home owners generally prefer to operate
their heater with the chimney damper closed.
This will put all the heat into the room. How-
ever, there may be times you will desire the
full flames of the highest heat setting but will
find the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
WARNING: Burners will
come on automatically within
one minute when the control
valve is in the ON position after
the pilot is lit.
20
1. STOP! Read the safety information on
page 19.
2. Make sure equipment shutoff valve is
fully open.
3. Set remote selector switch in the AUTO
position (see Figure 35).
4. Press in and turn control knob clockwise
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information on page 19. If you donʼt
smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 35).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the rear of the front
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
Ignitor
Button
Control Knob
Figure 35 - Remote Selector Switch,
Control Knob and Ignitor Button
www.desatech.com
to the OFF position (see Figure 35).
to the PILOT position.
Remote
Selector
Switch
AUTO
MAN
111604-01H