INSTALLATION
Continued
Installing Blower Accessory
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger-
ous operation.
CAUTION: Verify proper op-
eration after servicing.
Note: If you are using a mantel with your fireplace,
use the following instructions. If your fireplace is
built-in, see For Built-In Installation, page 15.
1. Install snap bushings found in blower kit into
hole in left side of outer casing and into one of
the holes in rear of remote/blower bracket.
2. Make sure the wire harness is firmly connected to
the terminals on the blower bracket assembly.
3. Note the wire locations on back of AUTO/
OFF/ON switch. The terminals on back of
switch are numbered 1, 2, and 3. Carefully
remove red wire from terminal 3 and blue
wire from terminal 1. Black wire can remain
on middle terminal 2 (see Figure 14).
4. Carefully disconnect green and white wires at
their insulated connectors (see Figure 15).
Blower
Bracket
Wire
Assembly
Harness
Screw
Switch
3
2
1
Switch
Plate
Wire
Harness
Figure 14 - Installing Blower Bracket
Assembly (Remote-Ready Unit Shown)
14
Wiring Routing
Hole in Baffle
Remote/
Blower
Bracket
www.desatech.com