oPERATiNG FiREPLAcE

FOR YOUR SAFETY READ
bEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
C. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING
INStRUCtIONS
NOtICE: During initial operation of new heater, burning
logs will give off a paper-burning smell. Orange flame
will also be present. Open damper or window to vent
smell. This will only last a few hours.
1. STOP! Read the safety information, above.
2. Turn off all electric power to the appliance.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise
position (see Figure 49). Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you don't smell gas,
go to the next step.
7. Turn equipment shutoff valve counterclockwise
the ON position. Do not force.
8. Close lower louver panel.
9. Turn on all electric power to the appliance.
10. Turn the wall switch to the ON position.
108862-01E
11. Visually locate the pilot. The ignitor should begin to spark and
the main burner should ignite once flame appears at pilot.
• If lighting the appliance for the first time each season,
it may take several attempts before the supply gas can
reach the pilot and main burners.
• If the appliance will not stay lit after several attempts,
follow the instructions To Turn Off Gas To Appliance, and
call your service technician or gas supplier.
Figure 49 - Turning Equipment Shutoff Valve to the OFF
Pilot Burner
1. Turn off the wall switch.
2. Turn off all electric power to the appliance if service is to
be performed.
3. Open lower louver panel.
4. Remove front hearth brick and control access panel.
to the OFF
5. Turn equipment shutoff valve clockwise
not force.
6. Close lower louver panel.
to
Note: The WRC receiver and hand-held remote control kit
must be purchased separately (see Accessories, page 29). Follow
installation instructions on page 21.
1. Turn equipment shutoff valve to ON position. You can
now turn the burner on and off with the hand-held remote
control unit.
IMPORTANT: Be sure to press the ON/OFF buttons on the
hand-held remote control unit for up to 3 seconds to assure
proper operation.
2. Press the ON/OFF button to turn the burner on and off.
www.desatech.com
Equipment Shutoff Valve
Position
Ignitor
Figure 50 - Pilot
TO TURN OFF GAS
tO APPLIANCE
OPTIONAL REMOTE
OPERATION
Adjustment Screw
Sensing
Rod
to OFF. Do