Fireplace Installation - Desa (V)T32EN-A Series, (V)T32EP-A Series Owner's Operation And Installation Manual

Direct-vent fireplace
Hide thumbs Also See for (V)T32EN-A Series, (V)T32EP-A Series:
Table of Contents

Advertisement

16
Figure 25 - Blower Model BK
Magnetic Strips
Exhaust
Port
Screw
www.desatech.com
5.
Mount speed control box to switch bracket by placing the plastic
control shaft forward through the opening in the switch bracket
(see Figure 26).
6.
While supporting speed control, secure control shaft with lock nut
by pushing and turning lock nut with pliers clockwise until it is
tight against front panel. Place control knob provided on shaft.
7.
Turn on power to duplex outlet if previously turned off per the
warning in column 1.
8.
Plug in blower power cord.
a. If your firebox is installed as a freestanding unit with an
accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Route power
cord through exit hole and plug the power cord into a wall
receptacle near the firebox.
b. If your firebox installation is recessed and/or pre-wired,
plug the power cord into the duplex outlet provided. Refer
to your firebox ownerʼs manual for instructions on wiring
the duplex outlet.
CAUTION: Never touch the blower wheel while
in operation.
9.
Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Turn blower on and check for operation. Turn blower off
by turning knob fully counterclockwise before continuing.
10. Peel off the backing paper and stick the supplied wiring diagram
decal on the firebox bottom approximately 12" in front of the
blower (see Figure 27).