Installation - Desa VYGF33PRC Owner's Operation And Installation Manual

Unvented (vent-free) gas fireplace
Table of Contents

Advertisement

INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system's circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install fire-
place. Follow all local codes.
WARNING: Make sure the
selector switch is in the OFF po-
sition before installing heater
WARNING: Never install the
fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing or other flammable objects
are less than 42 inches from the
front, top or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This fireplace cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating
heater where impurities (such
as, but not limited, to tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor
walls or cause odors.
8
Note: Your fireplace is designed to be used in zero
clearance installations. Wall or framing material can be
placed directly against any exterior surface on the rear,
sides or top of your fireplace, except where standoff
spacers are integrally attached. If standoff spacers are
attached to your fireplace, these spacers can be placed
directly against wall or framing materials.
Use the dimensions shown for rough openings to
create the easiest installation. See Built-In Fire-
place Installation, page 11.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing fire-
place in rooms without enough ventilation air may
cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, page 5.
IMPORTANT: Make sure the fireplace is level. If
fireplace is not level, log set will not work properly.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP)
for your fireplace. If your gas supply is not cor-
rect, do not install fireplace. Call dealer where you
bought fireplace for proper type fireplace.
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
ELECTRICAL HOOKUP
(Models GA3700 Series and GA3700T
Series Blower Accessories and GA3555
Internal Duplex Kit)
This fireplace accepts a blower assembly with an
electrical cord. The electrical cord is five feet in
length. You must locate fireplace within reach of
a 120 volt grounded electrical outlet. If not, you
must install an electrical outlet within reach of
fireplace power cord. The GA3555 outlet acces-
sory is used for built-in applications with blower
accessory installed.
INSTALLING HOOD
Install hood to top of firebox as shown in Figure 5.
Use 3 Phillips screws provided.
Figure 5 - Installing Hood to Firebox
www.desatech.com
WARNING: This appliance
113109-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vygf33nrcFpvf33nraFpvf33pra