Specifications; Replacement Parts; Service Hints; Technical Service - Desa Split Oak Design, American Oak Design Unvented Propane Gas Log Heater Model Split Oak and American Oak Design Owner's Operation And Installation Manual

Unvented (vent-free) propane gas log heater
Table of Contents

Advertisement

UNVENTED PROPANE GAS LOG HEATER

SPECIFICATIONS

18" Thermostat- 24" Thermostat- 30" Thermostat-
Controlled
Btu (Variable)
16,000/26,000
Type Gas
Propane Only
Ignition
Piezo
Manifold Pressure
7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
14"
Minimum*
11"
* For purpose of input adjustment
Shipping Weight
26 lbs.
Btu (Variable)
Type Gas
Ignition
Manifold Pressure
Inlet Gas
Pressure (in. of water)
Maximum
Minimum*
* For purpose of input adjustment
Shipping Weight

SERVICE HINTS

When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
Controlled
20,000/33,000
Propane Only
Piezo
7.9" W.C.
14"
11"
30 lbs.
18" Variable
24" Variable
Manually-
Manually-
Controlled
Controlled
16,000/26,000
20,000/33,000
Propane Only
Propane Only
Piezo
Piezo
7.9" W.C.
7.9" W.C.
14"
14"
11"
11"
26 lbs.
30 lbs.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International's Techni-
cal Service Department at
1-800-DESA LOG (1-800-337-2564).
REPLACEMENT
PARTS
Controlled
Note: Use only original replacement parts.
21,500/36,000
This will protect your warranty coverage for
parts replaced under warranty.
Propane Only
Parts Under Warranty
Piezo
Contact authorized dealers of this product.
7.9" W.C.
If they can't supply original replacement
part(s), call DESA International's Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have
14"
ready
11"
• your name
• your address
34 lbs.
• model number of your heater
• how heater was malfunctioning
30" Variable
• type of gas used (propane or natural gas)
Manually-
• purchase date
Controlled
Usually, we will ask you to return the defec-
21,500/36,000
tive part to the factory.
Propane Only
Parts Not Under Warranty
Piezo
Contact authorized dealers of this product.
If they can't supply original replacement
7.9" W.C.
part(s), call DESA International's Parts
Department at 1-800-972-7879 for referral
information.
When calling DESA International, have
14"
ready
11"
• model number of your heater
• the replacement part number
34 lbs.
22
103427