OPERATING APPLIANCE
Continued
6.
With control knob pressed in, push down and release ignitor
button. This will light pilot. The pilot is attached to the rear of
the front burner. If needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a qualifi ed service person
or gas supplier for repairs. Until repairs are made, light pilot
with match.
7. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7, pages 10 and
11.
8. Turn control knob counterclockwise
tion. Burner should light. If burner does not light, call a quali-
fi ed service person.
Pilot
Burner
Figure 19 - Thermocouple and Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1.
Turn control knob clockwise
2. Press in and turn control clockwise
tion.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
CLEANING AND
MAINTENANCE
• Keep the area around the log set clean and clear of debris.
• Occasionally, you may use a soft bristle brush to clean logs.
• Once every year a qualifi ed agency or certifi ed chimney sweep
should examine and clean the venting system of the fi replace.
to the ON posi-
Thermocouple
to the PILOT position.
to the OFF posi-
to the PILOT position.
For more information, visit www.desatech.com
Operating Instructions for GA9050A (Cont.)
To Turn Off Gas to Appliance

CLEANING AND MAINTENANCE

SERVICE HINTS

When Gas Pressure is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specifi ed heat
You may feel your gas pressure is too low. If so, contact your local
natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA's Technical Service Depart-
ment at 1-866-672-6040. When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA's technical services web site at www.
desatech.com.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply origi-
nal replacement part(s), call DESA's Technical Service Department
at 1-866-672-6040. When calling DESA, have ready:
• your name and address
• model and serial numbers of your log set
• how log set was malfunctioning
• type of gas used (natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply
original replacement part(s), call DESA at 1-866-672-6040 for
referral information. When calling DESA, have ready
• model number of your log set
• the replacement part number
OPERATING APPLIANCE
SERVICE HINTS
TECHNICAL SERVICE
REPLACEMENT PARTS