Thermal And Atmospheric Characteristics; Safety Characteristics - Intel SRCZCRX - RAID Controller Storage Hardware User's Manual

Hardware user guide
Table of Contents

Advertisement

3.3.5

Thermal and Atmospheric Characteristics

The Intel RAID Controller SRCZCRX has the following thermal, and atmospheric
characteristics.
The following parameters define the storage and transit environment for the Intel RAID
Controller SRCZCRX:
3.3.6

Safety Characteristics

The Intel RAID Controller SRCZCRX meets or exceeds the requirements of UL flammability
rating 94 V0. Each bare board is also marked with the supplier's name or trademark, type,
and UL flammability rating. Since these boards are installed in a PCI bus slot, all voltages
are below the SELV 42.4 V limit.
Technical Specifications
Temperature range: 0°C to 55°C (dry bulb)
Relative humidity range: 5% to 80% noncondensing
Maximum dew point temperature: 32°C
Airflow must be sufficient to keep the heat sink temperature below 80°C
Temperature range: − 40°C to + 115°C (dry bulb)
Relative humidity range: 20% to 80% noncondensing