Wiring Diagram; Service Hints; Specifications; Technical Service - Desa Comfort Glow LFP33PRA Owner's Operation And Installation Manual

Desa owner's operation and installation manual remote ready gas fireplace system lfp33pra
Table of Contents

Advertisement

UNVENTED PROPANE/LP GAS FIREPLACE

WIRING DIAGRAM

Note : For proper operation of optional ac-
cessories, the wires from the switch to the
control must be connected exactly as shown.

SPECIFICATIONS

LFP33PR Remote Ready
Btu (Variable)
Type Gas
Ignition
Pressure Manifold
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
* For input adjustment
LFP33PRA
Thermopile
20,000/33,000
Propane/LP Only
Piezo
8.0" W.C.
14"
11"
30 lbs. (24")/32 lbs.
(30")/34 lbs. (36")
22

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When Gas Quality Is Bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International's Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International's
technical
service
web
www.desatech.com.
site
at
107064