Local Codes; Unpacking; Product Features - Desa CGEFP33NRB Owner's Operation And Installation Manual

Sony operating instructions unvented (vent-free) gas fireplace cgefp33prb, cgefp33nrb
Table of Contents

Advertisement

LOCAL CODES

4

UNPACKING

PRODUCT FEATURES

LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the data plates attached
to the heater base assembly. The data plates contain
important warranty and safety information.
1. With utility knife, cut the carton all the way around above the
staples on the bottom tray. Lift the carton off the heater. Re-
move packing. Note: The hood is located in the packing on
the right hand side of the heater front. Lift the heater off the
bottom tray.
2. Locate two screws above top corners of the fireplace screen.
Remove and discard these screws. Lift fireplace screen up and
pull out to remove.
3. Remove protective packaging applied to logs, log base assem-
bly, and fireplace.
4. Remove fireplace hood from carton insert.
5. Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought fireplace.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
PRODUCT FEATURES
OPERATION
This vent-free fireplace is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a chimney. Heat is
generated by both realistic flames and glowing embers. When used
without the optional blower, the fireplace requires no electricity
making it ideal for emergency backup heat.
SAFETY DEVICE
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot system shuts off the fireplace if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches,
batteries, or other sources to light fireplace.
WIRELESS REMOTE CONTROL
This fireplace features an infrared wireless remote control. This
control system can be used to automatically light the pilot and adjust
the burner flame height at the push of a button.
WIRED WALL-MOUNTED REMOTE CONTROL
This fireplace features a two-button wall switch assembly with
glowing LED's. The wall switch performs the same functions as the
wireless hand-held remote control with the added feature of LED's
for visual feedback of operation and status.
OPTIONAL BLOWER ASSEMBLY
ACCESSORY
This fireplace accepts an optional blower assembly (not included).
The GA3650T/GA3700T Series blower operates thermostatically
and features a variable speed control. The GA3700/GA3750 Series
operates manually and also features a variable speed control. The
blower circulates heated air from the fireplace into the room. Use of
blower is optional. See Accessories, page 36.