INSPECTING
BURNER
103667
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the fireplace will
shut down.
Thermocouple
Figure 24 - Correct Pilot Flame Pattern
Thermocouple
Figure 25 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 25
• turn fireplace off (see To Turn Off Gas to Appliance, page 22).
• see Troubleshooting, pages 25 through 28.
Pilot Burner
Pilot Burner
23