OBSERVED PROBLEM
Heater produces a clicking/ticking noise
just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
Gas odor during combustion
For more information, visit www.desatech.com
CF26PR
WARNING: If you smell gas
building.
gas supplier's instructions.
POSSIBLE CAUSE
1. Metal expanding while heating or con-
tracting while cooling
1. Heater burning vapors from paint, hair
spray, glues, cleaners, chemicals, new
carpet, etc. (See IMPORTANT state-
ment above)
2. Gas leak. See Warning statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning statement at
top of page
2. Control valve defective
1. Foreign matter between control valve
and burner
2. Gas leak. See Warning statement at
top of page
www.desatech.com
REMEDY
1. This is common with most heaters. If
1. Open window and ventilate room. Stop
2. Locate and correct all leaks (see Check-
1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and
1. Locate and correct all leaks (see Check-
2. Replace control valve
1. Take apart gas tubing and remove for-
2. Locate and correct all leaks (see Check-
22
noise is excessive, contact qualified ser-
vice person
using odor causing products while heater
is running
ing Gas Connections, page 14)
Maintenance, page 19)
ing Gas Connections, page 14)
eign matter
ing Gas Connections, page 14)
105442