Vanguard B) Owner's Operation And Installation Manual page 9

Direct-vent fireplace
Table of Contents

Advertisement

VENTING
INSTALLATION
Continued
3. Attach vent pipe assembly to the fire-
place. Set fireplace in front of it's perma-
nent location to insure minimum clear-
ances. Mark the wall for a 10" square hole
(for noncombustible material such as
masonry block or concrete, a 7
eter hole is acceptable). See Figure 13.
The center of the hole should line up with
the center-line of the horizontal rigid vent
pipe. Cut a 10"x10" (254mm x 254mm)
square hole through combustible exterior
1
wall (7
/
" [190mm] diameter hole if
2
noncombustible). Frame as necessary
(see Figure 13).
4" Clamp
Female
7" Clamp
Locking
Lugs
Spacer
Spring
4" Flex
Male
Pipe
Slots
7" Flex
Pipe
Rigid Vent Pipe Flexible Vent Pipe
Figure 12 - Vent Pipe Connections
Vent Opening
Combustible Wall
10"
(254mm)
10"
(254mm)
(Framing
Detail)
Vent Opening
Noncombustible Wall
1
7
/
"
2
(190mm)
Figure 13 - Vent Opening Requirements
105539
4. Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7
1
/
" or 10" hole on the exterior
2
wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. At-
tach the vent cap with four wood screws
supplied (see Figure 14). Note : Re-
place the wood screws with appropri-
1
/
" diam-
ate fasteners for stucco, brick, concrete,
2
or other types of siding.
WARNING: Do not recess vent
termination in to any wall. This
will cause a fire hazard.
For vinyl siding use vinyl siding stand-
offs between vent cap and exterior wall.
The vinyl siding standoff prevents ex-
cessive heat from melting the vinyl sid-
ing material. Bolt the vent cap to the
standoff. Apply non-hardening mastic
around outside edge of the standoff in-
stead of the vent cap assembly. Use
wood screws provided to attach the
standoff. See Figure 15.
5. Slide the wall thimble over the vent pipe
before connecting the horizontal run to
the vent cap (see Figure 16).
Vent Cap
Figure 14 - Installing Horizontal Vent Cap
OWNER'S MANUAL
6.
7.
Figure 15 - Installing Vinyl Siding Stand-
off
Apply Mastic
to All Four
Sides
Wood
Screw
Vent Cap
(Horizontal
Termination)
Figure 16 - Connecting Vent Cap with
Horizontal Vent Pipe
9
Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should
be a minimum of 1
1
/
". Apply silicone
4
to the outer pipe connection. Fasten all
vent connections with screws provided.
Refer to Fireplace Installation on page
16 for instructions on securing unit to
framing or floor.
Slide the wall thimble against the inte-
rior wall surface and attach with screws
provided (see Figure 16).
Cut Vinyl Siding
Away to Fit
Standoff
Wood Screw
Nut
Apply Mastic
to All Four Sides
Vent Cap
Interior Wall
Surface
Screw
Horizontal
Vent Pipe
Standoff
Bolt
Wall
Thimble
Continued

Hide quick links:

Advertisement

Table of Contents
loading