Vanguard B) Owner's Operation And Installation Manual page 21

Direct-vent fireplace
Table of Contents

Advertisement

FIREPLACE
INSTALLATION
Continued
REMOVING/REPLACING
GLASS DOOR
You must remove glass door to install op-
tional brick liners, logs, lava rock, and em-
ber material.
CAUTION: Do not operate this
fireplace with a broken glass door
panel. Do not operate this fire-
place without the glass door panel
securely in place. For replace-
ment part information see Re-
placement Parts , page 31.
1. Remove the upper louver panel by lift-
ing upward and out (see Figure 41).
2. Remove the screws from the three tabs
at the top of the glass door while hold-
ing door securely keeping it from fall-
ing forward.
3. Grasp door by both sides and ease it
upward off of the lower bracket (see
Figure 42).
4. To replace glass door, follow the above
instructions in reverse.
Top Louver
Panel
Figure 41 - Removing Top Louver Panel
105539
Screw
Glass Door
Assembly
Lower Bracket for
Glass Door Assembly
Figure 42 - Removing/Replacing Glass Door
Attaching Magnetic Decorative
Brass Strips - DDV Only
The DDV fireplaces come with a set of two
magnetic decorative brass strips. Before at-
taching strips to fireplace, remove plastic
film from brass pieces. After installing the
door, attach these strips to the top and bot-
tom of the glass door frame.