Checking Gas Connections - Desa VVC36NE Series Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

FIREPLACE INSTALLATION
Continued
CAUTION: Use only new, black iron or steel
pipe. Internally-tinned copper tubing may be used in
certain areas. Check your local codes. Use pipe of
1/2" inside diameter or greater to allow proper gas
volume to fireplace. If pipe is too small, undue loss
of volume will occur.
Installation must include an equipment shutoff valve, union and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from fireplace (see Figure 31).
IMPORTANT: Install main gas valve (equipment shutoff valve)
in an accessible location. The main gas valve is for turning on or
shutting off the gas to the appliance.
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap/drip leg in supply
line as shown in Figure 31. Locate sediment trap/drip leg where it
is within reach for cleaning. Install in piping system between fuel
supply and fireplace. Locate sediment trap/drip leg where trapped
matter is not likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into fireplace gas con-
trols. If sediment trap/drip leg is not installed or is installed wrong,
fireplace may not run properly.
Approved Flexible
Gas Line
3" Minimum
Figure 31 - Gas Connection
116235-01C
CSA Design-Certified
Equipment Shutoff Valve
with 1/8" NPT Tap*
Natural - From
Gas Meter (5.5"
W.C. to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator (11"
W.C. to 14" W.C.
Pressure)
Cap
Pipe Nipple
Tee Joint
Sediment Trap/Drip Leg
www.desatech.com
FIREPLACE INSTALLATION
Installing Gas Piping to Fireplace Location (Cont.)
Connecting Fireplace To Gas Supply

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a
leak. Apply noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect fireplace and its individual equipment shutoff valve
from gas supply piping system. Pressures in excess of 1/2 psig
(3.5 kPa) will damage fireplace gas regulator.
2. Cap off open end of gas pipe where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas fireplace or opening main
gas valve located on or near gas meter for natural gas fireplace
or using compressed air.
4. Check all joints of gas supply piping system. Apply noncor-
rosive leak detection fluid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
5. Reconnect fireplace and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
Checking Gas Connections
19